MODE SELECTION
ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
265
Mode Selection
This feature allows the PowerScan 16K model to operate in one of two basic operative
modes:
• Normal Mode — data entered, either on the keypad or read via barcode, is trans
-
mitted to the host once the enter key is pressed, following the configured format
-
ting.
• Quantity/Code Mode — Can be further configured. See the next sections for Qty/
Code operations.
Quantity Field
This feature defines the behavior of the scanner if no data is entered in the QTY field so
that it is left empty. Options are:
• code is transmitted with default QTY (‘1’)
• code is transmitted alone (without any quantity information)
• code is discarded and an error beep is generated
Set Normal Mode
$CDISM00
$CDISM01
Set Qty Code Mode
Transmit code with default qty (‘1’)
$CPWEK00
$CPWEK01
Transmit Code only
Discard Code
$CPWEK02