ENTER/EXIT PROGRAMMING MODE
DISPLAY AND KEYBOARD FEATURES
264
POWERSCAN™ PD/PM/PBT9600
ADDITIONAL FEATURES FOR 16-KEY MODELS
See also "
Function Keys Configuration for 16-key Models Only" on page 258
Last Code Shown Timeout
After the code transmission, the last code read will be shown on the display for a config
-
urable timeout. If it is set to 00 it means that the code is not deleted from the display
even at the Display Off Timeout.
Display Time Stamping Mode
Time Stamping Mode can be applied when entering data from either a barcode, from
the keyboard, or both.
NOTE: The standard DISPLAY OFF TIMEOUT (see
) has a higher pri
-
ority than the LAST CODE SHOWN TIMEOUT, so the two parameters should
be combined to get the desired result.
Last Code Shown Timeout
$CDIST
To configure this feature, scan the ENTER/EXIT PRO
-
GRAMMING MODE bar code above, then the bar code
at left followed by 2 digits (00-99 sec. by 01) from the
End by scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
2 seconds
Applied to both
$CDITS00
$CDITS01
Applied only to barcode data
Applied only to keyboard data
$CDITS02