REFERENCES
185
5.10 DISPLAY PARAMETERS (SOME M8300 MODELS ONLY)
5.10.1 Display Mode
The user can control the reader display behavior according to the following
selections:
Normal mode
: When a barcode is read with the reader:
•
The code is sent to the Host.
•
The reader display is not cleared
•
There is no Local Echo to the reader display.
. Therefore if any previous data was displayed
on the reader screen it remains.
Clear Display After Decode mode
: When a barcode is read with the reader:
•
The code is sent to the Host.
•
The reader display is cleared
•
There is no Local Echo of the code to the reader display.
. Therefore if any previous data was displayed on
the reader screen it is cancelled and the screen remains blank.
Local Echo mode
: When a barcode is read with the reader:
•
The code is sent to the Host.
•
The reader display is cleared
•
The code is also sent to the reader display (Local Echo).
.
•
The cursor is positioned after the last printed character on the reader display.
Host messages sent to the reader
are always written to the reader display.