Programming Parameters
F-12
Pegaso™ Industrial PDA with Windows
®
CE
User ID
Specifies the symbology identifier (if any) that
is sent when parameter Send Code ID (Index
0025) is set to 3. "ASCII" code zero (null) is
used to indicate that an identifier is not to be
sent for the symbology
0125
Any single
ASCII
character
(00 = Off)
'X'
'X'
'X'
Universal Product Code-A (UPC-A)
Enter 1 for On
and 0 for Off.
Enable
Enables/disables the UPC-A symbology.
0500
On / Off
Off
On
On
Enable
Aggressive
Decoding
Enables more aggressive decoding algorithms
to be used in order to scan hard to read
labels.
0501
On / Off
Off
On
Off
Send Check
Digit
Includes check digit in the label which is trans-
mitted.
0502
On / Off
Off
On
Off
Send Sys-
tem Digit
Includes the system digit in the label transmis-
sion. For UPC-A, the system digit is always
zero.
0503
On / Off
Off
On
On
Convert UPC-
A to EAN-13
Instructs the decoder to expand UPC-A labels
to their EAN-13 equivalents. Any EAN-13
parameters will then apply to the result.
0504
On / Off
Off
On
Off
Read Verifi-
cation
Sets the number of times a label must be read
before it is transmitted.
0520
01 - 04
01
02
01
User ID
Specifies the symbology identifier (if any) sent
when parameter Send Code ID (Index 0025)
is set to 3. "ASCII" code zero (null) is used to
indicate that an identifier is not to be sent for
the symbology.
0521
Any single
ASCII
character
(00 = Off)
'A'
'A'
'A'
Universal Product Code-E (UPC-E)
Enter 1 for On
and 0 for Off.
Enable Sys-
tem Digit 0
Enables/disables UPC-E labels with a system
digit of zero.
0508
On / Off
Off
On
On
Enable
Aggressive
Decoding
Enables more aggressive decoding algorithms
to be used in order to scan hard to read
labels.
0509
On / Off
Off
On
Off
Send Check
Digit
Includes the check digit in the label which is
transmitted.
050A
On / Off
Off
On
Off
Send Sys-
tem Digit
This instructs the decoder to include the sys-
tem digit in the label transmission. For UPC-E,
the system digit is zero.
050B
On / Off
Off
On
Off
Code Parameter/ Description
I.D. #
Acceptable
Input
Defaults
Min
Max
Factory
Summary of Contents for Pegaso
Page 1: ...Industrial PDA with Windows CE Product Reference Guide ...
Page 10: ...Preface About this Guide viii Pegaso Industrial PDA with Windows CE NOTES ...
Page 14: ...Batteries and Power 1 4 Pegaso Industrial PDA with Windows CE NOTES ...
Page 46: ...Configuring the Pegaso 2 32 Pegaso Industrial PDA with Windows CE NOTES ...
Page 72: ...Networks Communications and Connections 4 10 Pegaso Industrial PDA with Windows CE NOTES ...
Page 98: ...Falcon Desktop Utility for Windows CE B 14 Pegaso Industrial PDA with Windows CE NOTES ...