Processor Outputs
MX-U81 Hardware Guide
Datalogic S.r.l.
4-6
Processor Outputs
The MX-U81 Processors contain sixteen general-purpose current-sink type output connections.
The table below describes the output’s electrical characteristics.
Note
: An external power source is required to power an output load. The outputs are merely switches that are open or
closed. All output connections must use properly grounded and shielded cable.
Note
: The Trigger Signal and Strobe Output for MX-U81 cameras are separate and not part of the MX-U81 Processor
inputs and outputs. See MX-U81 Cameras on page 3-1 for details.
Supply Voltage
+5 VDC (minimum) to +35 VDC (maximum)
Source Current
(maximum)
100 Milliamperes per output