TYPICAL LAYOUTS
90
MATRIX 320
ID-NET SYNCHRONIZED NETWORK
When the device is
working Synchronized
, the ID-NET connection is used to collect data
from several readers to build a multi-point or a multi-sided reading system; there can be
one Master and up to 31 Slaves connected together.
The Slave readers are connected together using the ID-NET interface. Every slave reader
must have an ID-NET address in the range 1-31.
The Master reader is also connected to the Host on one of its communication channels.
In the following examples the RS232/RS422 main serial interface is used.
For a Master/Slave Synchronized layout the External Trigger signal is unique to the sys-
tem; there is a single reading phase and a single message from the Master reader to the
Host computer.
It is not necessary to bring the External Trigger signal to all the read-
ers.
In the Master/Slave Synchronized layout the Master operating mode can only be set to
PackTrack or Phase Mode.
The Main and ID-NET interfaces are connected as shown in the following figures.
Host
Power
ID-NET
Master
Synchronized
ID-NET
Slave#1
Synchronized
ID-NET
Slave#n
Synchronized
Main Serial Interface (RS232 or RS422 Full-Duplex)
External Trigger
ID-NET (up to 16 devices - practical limit)
Figure 74 - ID-NET Synchronized Layout
The Master reader can be connected to the CBX series connection box with the advan-
tage of the Backup and Restore configuration function (CBX + BM100 module).
All devices always support multiple output channels (i.e. for data monitoring)
Summary of Contents for Matrix 320
Page 1: ...Matrix 320 PRODUCT REFERENCE GUIDE Image Based Industrial Reader...
Page 88: ...CBX ELECTRICAL CONNECTIONS 74 MATRIX 320 Figure 54 NPN External Trigger Using Matrix 320 Power...
Page 133: ...Reader 2 Reader 3 PASS THROUGH CONFIGURATIONS PRODUCT REFERENCE GUIDE 119...
Page 141: ...INTERNAL NETWORK CONFIGURATIONS PRODUCT REFERENCE GUIDE 127...
Page 143: ...INTERNAL NETWORK CONFIGURATIONS PRODUCT REFERENCE GUIDE 129 Open the cloned application job...