General Features
14
Magellan
TM
800i
Good Read: When to Indicate
This feature specifies when the scanner will provide indication (beep and/or flash its green LED)
upon successfully reading a bar code. Choices are:
•
Good Read = Indicate after decode
•
Good Read = Indicate after transmit
•
Good Read = Indicate after CTS goes inactive, then active
•
Good Read = Beep after each output structure proofed
NOTE
This option (Indicate after CTS goes inactive, then
active), which uses CTS, is only valid for RS-232 inter-
faces. If set to this mode in other interfaces, “Indicate
after decode” mode will be assumed. This setting will
only work if CTS Scan control is enabled.
NOTE
When beeping after each output structure decoded, if
multiple output structures, there is a delay after the
beep has finished. The delay is equal to the good beep
length or can be set by a ULE script.
START / END
PROGRAMMING BAR CODES
After Decode
DEFAULT
After Transmit
After CTS goes inactive, then active
Beep after each output structure proofed
009900(CR)
009901(CR)
009902(CR)
009903(CR)