Troubleshooting

Use this table to resolve common problems.

PROBLEM

SOLUTION

Scanner does not power-on

Exchange the power supply with a known 
good power supply and retest operation.

No communication with the host

Consult your technical support personnel or 
refer to your host system manual to verify 
the proper interface type, cable and con-
nection port(s) for the scanner. Verify the 
interface cable is securely attached to the 
host and the scanner.

The scanner will not read bar codes at 
all, or reads poorly

Make sure the window is clean. Check that 
the barcodes are of sufficient quality to be 
recognized by the scanner. Wrinkled, 
smudged, or torn labels can cause the 
scanner to not read at all. Scan known-
good labels of an active symbology

a

 to 

check the scanner's read operation.

a. Reading of the various barcode symbologies can be independently enabled or 

disabled in the scanner.

If the scanner still does not function properly, consult the Product Reference Guide 
(PRG) or contact your local supplier or Datalogic Customer Support Services.

Summary of Contents for MAGELLAN 3200VSI

Page 1: ...MagellanTM 3200VSi Omni Directional Imaging Scanner Quick Reference Guide...

Page 2: ...ur Datalogic representative Electronic versions may either be downloadable from the Data logic website www datalogic com or provided on appropriate media If you visit our website and would like to mak...

Page 3: ...domain 2 already in the receiving party s possession or rightfully known prior to receipt 3 rightfully learned from a third party not in violation of any other s proprietary rights or 4 independently...

Page 4: ...d User shall not disclose provide or otherwise make available the Proprietary Infor mation of Datalogic or its third party licensors to any person other than End User s autho rized employees or agents...

Page 5: ...N BETWEEN THE PARTIES CONCERNING SUCH CLAIMS AND WILL NOT BE MODIFIED OR AMENDED BY ANY PAST CON TEMPORANEOUS OR FUTURE AGREEMENTS OR DEALINGS BETWEEN THE PARTIES WHETHER ORAL OR WRITTEN EXCEPT AS SET...

Page 6: ...d with evidence of receipt Notices to Datalogic shall be sent to the attention of Contract Administration Datalogic Holdings Inc 959 Terry Street Eugene OR 97402 or such other address as may be specif...

Page 7: ...Nomenclature 1 Installation 2 Power Supply 3 How to Scan 3 Troubleshooting 4 Productivity Index Reporting Option 5 Scanner Push Button 5 LED and Beeper Indicators 7 Error Codes 9 WEEE Statement 10 Go...

Page 8: ...ominated diphenyl ethers PBDE Power supply X O O O O O Cable X O O O O O PCB Assembly Back Illumination X O O O O O PCB Assembly Main X O O O O O PCB Assembly Control Panel Illumination X O O O O O As...

Page 9: ...for viewing and download from the Datalogic website listed on the back cover of this manual Labeling and Nomenclature 1 Back Cover 8 P N Label 2 Scanner Push Button 9 USB SD Cover 3 Camera Push Butto...

Page 10: ...r code samples to verify correct opera tion The scanner should beep and or flash its good read LED1 and send the bar code data to the host or terminal If not use the Troubleshooting section of this gu...

Page 11: ...altena tively be programmed to initiate a scan of a cell phone or other LCD bar code object or an image capture upon pushing the Camera Push Button See the PRG for more details 1 Power Off the Termin...

Page 12: ...y attached to the host and the scanner The scanner will not read bar codes at all or reads poorly Make sure the window is clean Check that the barcodes are of sufficient quality to be recognized by th...

Page 13: ...r please refer to the Product Reference Guide PRG Scanner Push Button The Scanner Push Button also performs multiple functions depending upon the duration of time it is pressed NOTE Volume changes mad...

Page 14: ...three tones Stop when the desired tone high medium or low is sounded 4 Seconds Scanner Diagnostics Modea This mode allows system sup port personnel to troubleshoot problems with the scanner and is use...

Page 15: ...on indication Bright green flash Indicates the scanner has finished all its power up tests and is now ready for operation Good Read Indication Bright green flash Indicates a barcode has been read and...

Page 16: ...hed all its power up tests and is now ready for oper ation Good Read Indication Single beep The good read beep indication is configu rable Options include Enable disable frequency duration and volume...

Page 17: ...f it is configured to do so the scanner will sound a series of beeps corresponding to the error code and or flash its LED simultane ous to the beeps The table below describes what these codes mean and...

Page 18: ...ww datalogic com German Informationen zur Entsorgung von Elektro und Elektronik Altger ten WEEE erhalten Sie auf der Webseite www datalogic com Spanish Si desea informaci n acerca de los procedimiento...

Page 19: ...oing Green Thank you for using the bar code mask on the opposite side of this page This manual has been formatted to minimize the quan tity of pages needed to provide all of the programming bar codes...

Page 20: ...from the manual as indicated to create a sleeve through which bar codes start ing on the following page can be individually viewed and scanned It is important that only one bar code at a time be prese...

Page 21: ...Scan a Start End bar code once to enter Programming Mode After selecting scanning the interface scan the ENTER EXIT barcode a second time which will then accept your changes exit Programming Mode and...

Page 22: ...14 MagellanTM 3200VSi IBM 4683 Port 5B IBM 4683 Port 9B IBM 4683 Port 17 USB OEM START END...

Page 23: ...de 15 USB Keyboard USB COM Interface Keyboard Wedge A PC XT w alternate Key Encoding NOTE If other than Keyboard Wedge A with USA keyboard is needed see the PRG or On Screen Programming for additional...

Page 24: ...user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Con...

Page 25: ...day period starting from the date of shipment of the repaired product from Datalogic or until the expiration of the origi nal warranty period whichever is longer Datalogic does not guarantee and it i...

Page 26: ...er supply batteries keypads touch screen triggers etc No Assignment Customer may not assign or otherwise transfer its rights or obligations under this war ranty except to a purchaser or transferee of...

Page 27: ...nam LLC Lot I 4b Saigon High Tech Park Dist 9 Ho Chi Minh City Ph 84 837 30 8481 Placed into EU Service June 16 2010 Declaration updated April 2013 Council Directives EMC 2004 108 EC Low Voltage 2006...

Page 28: ...ogic ADC Inc All rights reserved Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S A and the E U Datalogic ADC Inc 959 Terry Street Euge...

Reviews: