RGB Good Read Raising/Falling Time
This parameter specifies the time it will take for the RGB good read to change
the status from an Off state to Brightness state, or back.
The delay can be set within a range of zero (0) to 160000 milliseconds (16 sec-
onds) in 100ms increments. A setting of zero specifies no delay.
To set the time:
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the
result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05,
20 = 20, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Program-
ming Mode.
4. Scan the bar code: SELECT RGB GOOD READ RAISING TIME on
or
RBG GOOD READ FALLING TIME on
5. Scan the appropriate two digits from the keypad in
, that
represent the duration which was determined in the steps above.
NOTE
If you make a mistake before the last character, scan the CANCEL bar code
to abort and not save the entry string. You can then start again at the
beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit.
This completes the procedure. See the following table for examples of how to
set this feature.
Table 14. RGB Good Read Raising/Falling Time Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
100ms
200ms
1000ms (1 sec.)
5000ms (5 secs.)
2
Divide by 100
01
02
10
50
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT RGB GOOD READ RAISING/FALLING TIME
5
Scan Two Characters From
‘0’ and ‘1’
‘0’ and ‘2’
‘1’ and ‘0’
‘5’ and ‘0’
6
Scan ENTER/EXIT PROGRAMMING MODE
Summary of Contents for Heron HD3430
Page 1: ...Heron HD3430 2D Area Imager Product Reference Guide ...
Page 12: ...Introduction 4 Heron HD3430 NOTES ...
Page 34: ...Enter Exit Programming Mode Parity 26 Heron HD3430 CR2PA01 Parity Even CR2PA02 Parity Odd ...
Page 36: ...RS 232 ONLY Interface 28 Heron HD3430 NOTES ...
Page 78: ...Keyboard Interface 70 Heron HD3430 ...
Page 122: ...Reading Parameters 114 Heron HD3430 NOTES ...
Page 210: ...Enter Exit Programming Mode BC412 200 Heron HD3430 NOTES ...
Page 242: ...Symbology Selection 232 Heron HD3430 NOTES ...
Page 280: ...Technical Specifications 270 Heron HD3430 Stand Dimensions ...
Page 282: ...Technical Specifications 272 Heron HD3430 NOTES ...
Page 294: ...Standard Defaults 284 Heron HD3430 NOTES ...