5.12 DEFAULT PARAMETERS FOR POS TERMINALS
The default values of the RS232 and Data Format parameters for POS terminals are
listed in the following table:
NIXDORF Mode A
FUJITSU
ICL Mode
RS232 Group
Baud Rate
9600
9600
9600
Parity Odd
None
Even
Data Bits
8
8
8
Stop Bits
1
1
1
Handshaking
Hardware (RTS/CTS)
None
RTS always ON
ACK/NACK Protocol
Disabled
Disabled
Disabled
FIFO Disabled
Enabled
Enabled
Inter-Character Delay
Disabled
Disabled
Disabled
RX Timeout
9.9 sec
2 sec
9.9 sec
Serial Trigger Lock
Disabled
Disabled
Disabled
Data Format Group
Code Identifier
Custom
Custom
Custom
Header
No Header
No Header
No Header
Terminator CR
CR
CR
Field Adjustment
Disabled
Disabled
Disabled
Code Length TX
Not Transmitted
Not Transmitted
Not Transmitted
Character Replacement
Disabled Disabled Disabled
Address Stamping
Disabled
Disabled
Disabled
Address Delimiter
Disabled
Disabled
Disabled
The table below lists all the Code Identifiers available for the POS terminals:
CODE
NIXDORF Mode A
FUJITSU
ICL Mode
UPC-A A0
A
A
UPC-E C0
E
E
EAN-8 B
FF
FF
EAN-13 A
F
F
Code 39
M
None
C [code length]
Codabar N
None
N
[code
length]
Code 128
K
None
L [code length]
Interleaved 2 of 5
I
None
I [code length]
Code 93
L
None
None
Industrial 2 of 5
H
None
H [code length]
UCC/EAN 128
P
None
L [code length]
MSI/Plessey O
None
None
RSS E
None
None
PDF417 Q
None
None
Other None
None
None
Summary of Contents for GRYPHON
Page 12: ...GRYPHON 4 2 3 RS232 CONNECTION 2 4 USB ...
Page 13: ...INSTALLATION 5 2 5 IBM USB POS 2 6 WEDGE CONNECTION ...
Page 14: ...GRYPHON 6 2 7 PEN EMULATION CONNECTION ...
Page 67: ...59 ...
Page 76: ...Enter Configuration Exit and Save Configuration Ì Î DATA FORMAT Ì Î 68 ...
Page 86: ...Enter Configuration Exit and Save Configuration Ì Î POWER SAVE Ì Î 78 ...
Page 98: ...90 ...
Page 120: ...Enter Configuration Exit and Save Configuration Ì Î CODE SELECTION Ì Î 112 ...
Page 138: ...Exit and Save Configuration ADVANCED FORMATTING Ì Î 130 end Format 4 definition ÌHM3uÎ ...