1D Code Selection
Enter/Exit Programming Mode
Product Reference Guide
169
Industrial 2 of 5 Check Character Transmission
Enables/disables transmission of an Industrial 2 of 5 check character.
Industrial 2 of 5 Length Control
This feature specifies either variable length decoding or fixed length decod-
ing for the Industrial 2 of 5 symbology.
Variable Length:
For variable length decoding, a minimum and maximum
length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
$CU2LC00(CR)
Industrial 2 of 5 Length Control = Variable Length
$CU2LC01(CR)
Industrial 2 of 5 = Fixed Length
Industrial 2 of 5 Check Character Transmission = Disable
Industrial 2 of 5 Check Character Transmission = Enable
$CU2CT00(CR)
$CU2CT01(CR)
DEFAULT
DEFAULT