background image

Technical Specifications

Quick Reference Guide

39

Depth of Field (Typical)

a

a

13 mils DOF based on EAN. All other 1D codes are Code 39. All labels grade A, 
typical environmental light, 20°C, label inclination 10°

Symbology

SR:

HD:

Code 39 

5mil: 2” - 4.7” (5 - 12cm); 
10mil: 1.2” - 9.8” (3 - 25cm); 
20mil: up to 15.7” (40cm)

3mil: 0.9” - 3.6” (2.4 - 9.1cm)
5 mil: 0.3” - 4.5” (0.8-11.3cm)

EAN 

13mil: 0.8” - 13” (2 - 33cm);
7.5mil: 1.6 - 8.3” (4 - 21cm)

13mil: 4.3” - 6.8” (1.1- 17.2cm);
7.5mil: 0 - 5” (0 - 12.7cm)

PDF-417

6.6mil: 1.6” - 4.7” (4 - 12cm);
10mil: 0.4” - 8.3” (1 - 21cm);
15mil: 0.8” - 11.8” (2 - 30cm)

4mil: 0.7” - 2.7” (1.8 - 6.8cm);
6.6mil: 0.04” - 4.4” (0.1 - 11.2cm);
10mil: 0” - 5.6” (0 - 14.3cm)

DataMatrix

10mil: 0.6” to 5.9” (1.5 - 15cm)
15mil: 1.6” to 9.3” (4 - 23.5cm)

5mil: 1.1” - 2.4” (2.8-6.1cm)

QR Code

10mil: 1.6” to 4.9” (4 - 12.5cm)
15mil: 0.6” to 7.3” (1.5 - 18.5cm)

6.7mil: 0.8” - 1.7” (2.1 - 4.2cm)

Min DataMatrix

7 mil

 5 mil

Minimum Ele-
ment Width

Standard Range:

1D Minimum Resolution = 4 mil
PDF-417 Minimum Resolution = 5 
mil
Datamatrix Minimum Resolution = 
6 mil

High Density:

1D Minimum Resolution = 2.5 mil
PDF-417 Minimum Resolution = 4 
mil
Datamatrix Minimum Resolution = 
5 mil

Print Contrast 
Minimum

25% minimum reflectance

Summary of Contents for Gryphon I GBT4400 2D

Page 1: ...Gryphon I GBT44002D General Purpose Handheld Area Imager Bar Code Reader with Bluetooth Wireless Technology Quick Reference Guide...

Page 2: ...ting your Datalogic represen tative Electronic versions may either be downloadable from the Datalogic website www scanning datalogic com or provided on appropriate media If you visit our website and w...

Page 3: ...Charging the Batteries 13 Battery Safety 13 Replacing the Batteries 16 Using the Gryphon I GBT4400 2D 18 Linking the Reader 19 Link Datalogic RF Devices to Base 19 Link Scanner to Bluetooth Adapter 1...

Page 4: ...s 42 Error Codes 45 Base Station Indications 46 Statement of Agency Compliance 47 FCC Class B Compliance Statement 47 FCC RF Radiation Exposure Statement 48 Canadian Notice 48 Power Supply 48 Imager L...

Page 5: ...include any information that the receiving party can establish was 1 in the public domain 2 already in the receiving party s possession or rightfully known prior to receipt 3 rightfully learned from...

Page 6: ...ho are under confidentiality agreement and End User shall not use the Proprietary Information other than in conjunction with use of the Datalogic Product exclusively for End User s internal business p...

Page 7: ...ation Of Liability EXCEPT AS PROVIDED IN SECTION 7 DATALOGIC SHALL NOT BE LIABLE FOR ANY CLAIMS AGAINST END USER BY ANY OTHER PARTY IN NO EVENT SHALL DATALOGIC S LIABILITY FOR DAMAGES IF ANY WHETHER B...

Page 8: ...Agree ment except that Datalogic shall have the right at its absolute discretion to initiate proceedings in the courts of any other state country or territory in which End User resides or in which an...

Page 9: ...al reader so the orientation of the symbol is not important Datalogic s exclusive patented Green Spot for good read feedback helps to improve productiv ity in noisy environments or in situations where...

Page 10: ...ositions either a horizontal or standing position in order to provide the most comfortable use depending on needs Changing the Base Station Position The base station is configured by installing one of...

Page 11: ...e 7 1 Insert the appropriate parts for the desired base station position as shown below 2 Using your thumbs push open the plastic tabs on the bottom of the base to free the wing holders Standing Horiz...

Page 12: ...eeding Connect the interface cable be fore applying power to the Base Station Base Station Connection and Routing Fully insert the Power Ca ble and Interface I F Cable connectors into their respective...

Page 13: ...outing of the power cord can be changed to accommodate the base station positioning hori zontal stand or wall mounting The cables can be looped around to the front of the Base Station or fed directly...

Page 14: ...n in Figure 4 on page 10 Keyboard Wedge interface cables have a Y con nection where its female end mates with the male end of the cable from the keyboard and the remaining end at the key board port on...

Page 15: ...base as shown in Figure 5 Figure 5 Disconnecting the Cable System and Network Layout Typical Setup with Cradle and Host Figure 6 Reader Layout Gryphon 2D GBT can also be Powered by the Terminal The ex...

Page 16: ...tware tool to force a BT disconnect and for paging the scanner when it is activated Refer to the Gryphon 2D Product Reference Guide PRG for a more de tailed explanation LED STATUS Power on Data Yellow...

Page 17: ...the Battery read Battery Safety in the follow ing section Datalogic recommends annual replacement of rechargeable battery packs to ensure maximum perfor mance WARNING Do not discharge the battery usi...

Page 18: ...ater and immediately seek medical care If left untreated the bat tery fluid could cause damage to the eye CAUTION Always charge the battery at 32 104 F 0 40 C tem perature range Use only the authorize...

Page 19: ...ue to use a battery that is showing excessive loss of capacity it should be properly recycled disposed of and replaced For most ap plications batteries should be replaced after one year of service to...

Page 20: ...nd remove the two screws securing the battery holder 3 Carefully lift out the gold contacts circuit and remove the battery holder cap while letting the white connec tor pass through the hole in the ba...

Page 21: ...osition 5 Replace the battery holder cap plug in the connector and return the contacts circuit to its previous location 6 Insert the cover in the handle and screw it back into place When inserting the...

Page 22: ...ld of view indicated by the aiming system will be smaller when the reader is closer to the bar code and larger when it is farther from the code Symbologies with smaller bars or elements mil size shoul...

Page 23: ...first scan the Unlink barcode before re linking to the new base Link Scanner to Bluetooth Adapter 1 Install any drivers provided with the Bluetooth adapter 2 Scan the Enable RF Link to Server label be...

Page 24: ...els RS 232 RS 232 OPOS USB IBM 46XX Information and programming options for each interface type are provided in this section For defaults and additional infor mation associated with each interface pro...

Page 25: ...ck Reference Guide 21 RS 232 RS 232 standard interface Select RS232 STD RS 232 Wincor Nixdorf Select RS232 WN RS 232 for use with OPOS UPOS JavaPOS Select RS 232 OPOS USB Com to simulate RS 232 standa...

Page 26: ...I GBT4400 2D IBM IBM 46xx Port 5B reader interface Select IBM P5B IBM 46xx Port 9B reader interface Select IBM P9B USB OEM USB OEM can be used for OPOS UPOS JavaPOS Select USB OEM a Download the corre...

Page 27: ...PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Standard Key Encoding Select KBD AT Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard Select KBD AT NK AT PS 2 25 286 30...

Page 28: ...Terminal 3153 Select KBD IBM 3153 Keyboard Wedge for IBM Terminals 31xx 32xx 34xx 37xx make only keyboard Select KBD IBM M Keyboard Wedge for IBM Terminals 31xx 32xx 34xx 37xx make break keyboard Sele...

Page 29: ...60 70 80 90 95 w Std Key Encoding Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 without Alternate Key Keyboard Wedg...

Page 30: ...ype 26 Gryphon I GBT4400 2D COUNTRY MODE ENTER EXIT PROGRAMMING MODE Country Mode U S Country Mode Belgium Country Mode Britain Country Mode Croatia Supports only the interfaces listed in the Country...

Page 31: ...ference Guide 27 COUNTRY MODE Continued Country Mode Czech Country Mode Denmark Country Mode France Country Mode Germany Country Mode Hungary Country Mode Italy Supports only the interfaces listed in...

Page 32: ...GBT4400 2D COUNTRY MODE Continued Country Mode Japanese 106 key Country Mode Norway Country Mode Poland Country Mode Portugal Country Mode Romania Country Mode Spain Supports only the interfaces liste...

Page 33: ...the Interface Type Quick Reference Guide 29 COUNTRY MODE Continued Country Mode Sweden Country Mode Slovakia Country Mode Switzerland Supports only the interfaces listed in the Country Mode feature de...

Page 34: ...the format in which the reader sends character data This applies to keyboard wedge interfaces This does not apply when an alternate key encoding keyboard is se lected ENTER EXIT PROGRAMMING MODE Caps...

Page 35: ...tion specifies the setting of the Numbers Lock Num lock key while in keyboard wedge interface This only applies to alternate key encoding interfaces It does not apply to USB keyboard ENTER EXIT PROGRA...

Page 36: ...EXIT barcode once to enter Programming Mode scan the desired parameter settings scan the ENTER EXIT barcode again to accept your changes which exits Programming Mode and re turns the reader to normal...

Page 37: ...riefly switch off during the acquisition time and if no code is decoded will switch on again before the next acquisition The illuminator will remain on until the symbol is decoded As you read code sym...

Page 38: ...led by a good read green spot Use the barcodes below to specify the duration of the good read pointer beam after a good read ENTER EXIT PROGRAMMING MODE Green Spot Duration Disable Green Spot is Off G...

Page 39: ...nd re leased scanning is activated until programmable duration1 has elapsed or the trigger has been pulled again to transition to another state Double Read Timeout1 prevents undesired multiple reads w...

Page 40: ...36 Gryphon I GBT4400 2D SCAN MODE ENTER EXIT PROGRAMMING MODE Scan Mode Trigger Single Scan Mode Trigger Hold Multiple Scan Mode Trigger Pulse Multiple Scan Mode Flashing Scan Mode Always On Scan Mode...

Page 41: ...in Trig ger Single mode If the scanner switches to a different Read Mode Pick Mode is automatically disabled Multiple Labels in a Volume Enables disables the ability of scanner to decode multiple la...

Page 42: ...Ionbatterypack Chargetimeforfullcharge fromfulldischarge 4hourswithexternalpowersupplyadaptera a Charge Times are much lower when battery is within daily typical operating condition typical16hourswith...

Page 43: ...0 12 7cm PDF 417 6 6mil 1 6 4 7 4 12cm 10mil 0 4 8 3 1 21cm 15mil 0 8 11 8 2 30cm 4mil 0 7 2 7 1 8 6 8cm 6 6mil 0 04 4 4 0 1 11 2cm 10mil 0 5 6 0 14 3cm DataMatrix 10mil 0 6 to5 9 1 5 15cm 15mil 1 6 t...

Page 44: ...areorRectangularStyle Datalength 1 3600 characters Maxicode QRCodes QR MicroQRandMultipleQRCodes Aztec PostalCodes AustralianPost JapanesePost KIXPost PlanetCode Postnet RoyalMailCode RM45CC Intellige...

Page 45: ...ANADA FCC IC Japan JRF VCCI Mexico NOM Cofetel SouthKorea KCC Brazil ANATEL Argentina CNC China SRRC Malaysia SIRIM Indonesia Singapore IDA Taiwan NCC LaserClassSafety IECClass2 Radiation1mWAvg Emitte...

Page 46: ...aderbeepsfour timesathighest frequencyandvol umeuponpower up GoodRead Beep Alabelhasbeensuc cessfullyscannedby thereader LEDbehaviorfor thisindicationis configurablevia thefeature Good Read Whento Ind...

Page 47: ...essfulread ofalabel thesoft wareshallturnthe greenspotonforthe timespecifiedbythe configuredvalue N A N A ImageCap ture Whenreadytocap tureimage Bluelightflashes 2 times when updating N A aExceptwheni...

Page 48: ...rrentvol ume LabelProgramming ModeAcceptanceof PartialLabel Incaseswheremulti plelabelsmustbe scannedtoprogram onefeature thisindi cationacknowledges eachportionasitis successfullyscanned N A Readerso...

Page 49: ...nd has entered FRU Field Replaceable Unit isolation mode If the reader is reset the sequence will be repeated The following table de scribes the LED flashes beep codes associated with an error found N...

Page 50: ...LED blinking 1Hz Data labels are transmitted to the HOST Yellow LEDs turned off for 100mSec Programming Mode Yellow LED blinks quickly Configuration alignment with the HH is in progress Red LED blinks...

Page 51: ...pment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful i...

Page 52: ...e bruits radioelec triques depassant les limites applicables aux appareils nume riques de la classe B prescrites dans le Reglement sur le brouillage radioelectrique edicte par le ministere des Commu n...

Page 53: ...nta ins FC C ID 09N DL BT MC X IC 386 2A DL BT MC X N2 63 Se e pro duc t ma nua l and pac kag e for pat ent list ing AC CES SO RY LIS TED I T E 3K RU Scanner Regulatory Label Base Station Label DO NO...

Page 54: ...VISI BLE L OEIL NU ET IL EST MIS PAR LA FEN TRE D SIGN E SUR L ILLUSTRA TION DANS LA FIGURE ALUZL SERES VISIBLE AL OJO HUMANO Y ES EMITIDA POR LA VENTANA INDICADA EN LA FIGURA LUCE LASER NON FISSARE...

Page 55: ...motivi di installazione utilizzo o manutenzione Il prodotto utilizza un diodo laser a bassa potenza Sebbene non siano noti danni riportati dall occhio umano in seguito ad una esposizione di breve dur...

Page 56: ...DE SECURITE LASER Ce produit est conforme aux normes de s curit laser en vi gueur sa date de fabrication CDRH 21 CFR 1040 et EN 60825 1 Il n est pas n cessaire d ouvrir l appareil pour l installation...

Page 57: ...iliza un diodo l ser a baja potencia No son noto rios da os a los ojos humanos a consecuencia de una ex posici n de corta duraci n Eviten de mirar fijo el rayo l ser as como evitar an cualquiera otra...

Page 58: ...anning datalogic com German InformationenzurEntsorgung von Elektro undElektronik Altger ten WEEE erhalten Sie auf der Webseite www scanning datalogic com Spanish Si desea informaci n acerca de los pro...

Page 59: ...e product maintenance including but not limited to cleaning of the upper window in accordance with product manual installation or service of product by other than Dat alogic representatives use of pro...

Page 60: ...orrect heights Reduce or eliminate vibration Reduce or eliminate direct pressure Provide adjustable workstations Provide adequate clearance Provide a suitable working environment Improve work procedur...

Page 61: ...Datalogic Aladdin a multi platform utility program that allows device configuration using a PC It pro vides RS 232 interface configuration as well as config uration bar code printing Service Support T...

Page 62: ...Services and Support 58 Gryphon I GBT4400 2D NOTES...

Page 63: ...menentspricht Estadeclaraci nsebasaenelcumplimiento de losproductosconlassiguientesnormas EC 063 Rev 0 Pag 1 di 1 Datalogic Scanning Inc 959 Terry Street Eugene Oregon 97402 USA e tuttiisuoimodelli an...

Page 64: ...Japan DatalogicScanningKK Telephone 81 0 334916761 japan scanning datalogic com LatinAmerica DatalogicScanning Inc Telephone 305 591 3222 latinamerica scanning datalogic com Singapore DatalogicScannin...

Reviews: