LED and Beeper Indications
388
Gryphon™ I GD4100/GM4100
Table 50
Programming Mode
- The following indications ONLY occur when the reader is in Programming Mode.
Label Program-
ming Mode
Entry
A valid programming label has
been scanned.
LED blinks continuously
Reader sounds four low frequency beeps.
Label Program-
ming Mode
Rejection of
Label
A label has been rejected.
N/A
Reader sounds three times at
lowest frequency & current vol-
ume.
Label Program-
ming Mode
Acceptance of
Partial Label
In cases where multiple labels
must be scanned to program
one feature, this indication
acknowledges each portion as
it is successfully scanned.
N/A
Reader sounds one short beep at highest
frequency & current volume.
Label Program-
ming Mode
Acceptance of
Programming
Configuration option(s) have
been successfully programmed
via labels and the reader has
exited Programming Mode.
N/A
Reader sounds one high fre-
quency beep and 4 low fre-
quency beeps followed by
reset beeps.
Label Program-
ming Mode Can-
cel Item Entry
Cancel label has been scanned.
N/A
Reader sounds two times at
low frequency and current vol-
ume.
. Programming Mode Indications
Error Codes
Upon startup, if the reader sounds a long tone, this means the reader has not passed its
automatic Selftest and has entered FRU (Field Replaceable Unit) isolation mode. If the reader is
reset, the sequence will be repeated. The following table describes the LED flashes/beep codes
associated with an error found.
NUMBER OF LED
FLASHES/BEEPS
ERROR
CORRECTIVE ACTION
1
Configuration
Contact Helpdesk for assistance
2
Interface PCB
4
Reader Module
5
Laser Pointer (if so equipped)
6
Digital PCB
14
CPLD/Code Mismatch
Summary of Contents for Gryphon GD4100
Page 14: ...Introduction 12 Gryphon I GD4100 GM4100 NOTES ...
Page 34: ...Getting Started 32 Gryphon I GD4100 GM4100 NOTES ...
Page 68: ...General Features 66 Gryphon I GD4100 GM4100 NOTES ...
Page 80: ...RS 232 ONLY Interface 78 Gryphon I GD4100 GM4100 NOTES ...
Page 100: ...RS 232 USB Com Interfaces 98 Gryphon I GD4100 GM4100 NOTES ...
Page 118: ...USB OEM Interface 116 Gryphon I GD4100 GM4100 NOTES ...
Page 130: ...Wand Emulation Interface 128 Gryphon I GD4100 GM4100 NOTES ...
Page 154: ...Data Editing 152 Gryphon I GD4100 GM4100 NOTES ...
Page 392: ...LED and Beeper Indications 390 Gryphon I GD4100 GM4100 NOTES ...
Page 408: ...Sample Barcodes 406 Gryphon I GD4100 GM4100 NOTES ...
Page 410: ...Keypad 408 Gryphon I GD4100 GM4100 6 7 8 9 ...
Page 411: ...Keypad Product Reference Guide 409 A B C D E F ...
Page 412: ...Keypad 410 Gryphon I GD4100 GM4100 NOTES ...
Page 422: ...420 Gryphon I GD4100 GM4100 IBM XT Table 60 Scancode Set When Control Character is 00 or 01 ...
Page 423: ...Product Reference Guide 421 IBM XT cont Table 61 Scancode Set When Control Character is 02 ...