Data Editing
150
Gryphon™ I GD4100/GM4100
Character Conversion
Character conversion is an eight byte configuration item. The eight bytes are 4 character pairs
represented in hexadecimal ASCII values. The first character in the pair is the character that will
be converted. The second character in the pair is the character to convert to. If the character to
convert in a pair is FF, then no conversion is done.
For example, if you have the character conversion configuration item set to the following:
41423132FFFFFFFF
The first pair is 4142 or AB (41 hex is an ASCII capital A, 42 hex is an ASCII capital B) and the
second pair is 3132 or 12 (31 hex is an ASCII 1, 32 is an ASCII 2). The other two pairs are
FFFF and FFFF.
With the label, AB12BA21, it would look as follows after the character
conversion: BB22BB22.
The A characters were converted to B characters and the 1 characters were converted to 2
characters. Nothing is done with the last two character pairs, since they are all FF.
To set Character Conversion:
1. Scan the ENTER/EXIT barcode.
2. Scan the “Configure Character Conversion” barcode.
3. Determine the desired string. Sixteen positions must be determined as in the above exam-
ple. Next, turn to the ASCII Chart on the inside back cover of this manual and find the
equivalent hex digits needed to fulfill the string.
4. Turn to Appendix E, Keypad and scan the barcodes representing the hex characters deter-
mined in the previous step.
5. Scan the ENTER/EXIT barcode to exit Programming Mode.
NOTE
If less than the expected string of 16 characters are selected,
scan the ENTER/EXIT barcode twice to accept the selections
and exit Programming Mode.
Summary of Contents for Gryphon GD4100
Page 14: ...Introduction 12 Gryphon I GD4100 GM4100 NOTES ...
Page 34: ...Getting Started 32 Gryphon I GD4100 GM4100 NOTES ...
Page 68: ...General Features 66 Gryphon I GD4100 GM4100 NOTES ...
Page 80: ...RS 232 ONLY Interface 78 Gryphon I GD4100 GM4100 NOTES ...
Page 100: ...RS 232 USB Com Interfaces 98 Gryphon I GD4100 GM4100 NOTES ...
Page 118: ...USB OEM Interface 116 Gryphon I GD4100 GM4100 NOTES ...
Page 130: ...Wand Emulation Interface 128 Gryphon I GD4100 GM4100 NOTES ...
Page 154: ...Data Editing 152 Gryphon I GD4100 GM4100 NOTES ...
Page 392: ...LED and Beeper Indications 390 Gryphon I GD4100 GM4100 NOTES ...
Page 408: ...Sample Barcodes 406 Gryphon I GD4100 GM4100 NOTES ...
Page 410: ...Keypad 408 Gryphon I GD4100 GM4100 6 7 8 9 ...
Page 411: ...Keypad Product Reference Guide 409 A B C D E F ...
Page 412: ...Keypad 410 Gryphon I GD4100 GM4100 NOTES ...
Page 422: ...420 Gryphon I GD4100 GM4100 IBM XT Table 60 Scancode Set When Control Character is 00 or 01 ...
Page 423: ...Product Reference Guide 421 IBM XT cont Table 61 Scancode Set When Control Character is 02 ...