Enter/Exit Programming Mode
262
Gryphon™ I GD44XX/GBT4400/GM440X
Motion Sensitivity
Defines discrete set of levels for scanner motion sensitivity when in hand-
held use.
Motion Sensitivity = Low
Motion Sensitivity = Medium
Motion Sensitivity = High
Motionless Timeout
Specifies the waiting time in 100 millisecond ticks to assume that the reader
is in a motionless condition. The selectable range is 500 msec to 25.5 Sec-
onds. When no motion event is detected for a period of time longer than this
timeout, the software assumes the reader is in a motionless condition. This
normally results in returning the scanner to Stand Mode. This option relates
to such features as Aimer On and Stand Mode Object Sense scanning with
respect to motion. See "
Motionless Timeout" on page 305
in References.
$CMOTO
Select Motionless Timeout Setting
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code
at left followed by three digits from the Alphanumeric
characters in
representing
your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start again
at the beginning.
~
CANCEL
$CMOSY00(CR)
$CMOSY01(CR)
DEFAULT
$CMOSY02(CR)
DEFAULT
020 = Motionless Timeout = 2 seconds
Summary of Contents for GBT4400BK
Page 42: ...Setup 32 Gryphon I GD44XX GBT4400 GM440X ...
Page 46: ...Enter Exit Programming Mode 36 Gryphon I GD44XX GBT4400 GM440X NOTES ...
Page 60: ...Enter Exit Programming Mode 50 Gryphon I GD44XX GBT4400 GM440X NOTES ...
Page 102: ...Enter Exit Programming Mode 92 Gryphon I GD44XX GBT4400 GM440X NOTES ...
Page 248: ...238 Gryphon I GD44XX GBT4400 GM440X NOTES ...
Page 308: ...References 298 Gryphon I GD44XX GBT4400 GM440X NOTES ...
Page 338: ...Keypad 328 Gryphon I GD44XX GBT4400 GM440X A B C D E F ...
Page 348: ...Scancode Tables 338 Gryphon I GD44XX GBT4400 GM440X NOTES ...