Aux Serial Port
Reference Manual
101
Aux Serial Port
Use the Aux Serial Port window to configure communication through the Auxil-
iary Serial Port. For this communication mode, RS232 interface is automatically
selected.
To edit the Aux Serial Port settings:
1. In the menu under Modify Settings, navigate to Global Settings | Serial Ports
| Aux Serial Port. The Aux Serial Port window opens.
2. Enter the appropriate information in the form as described below:
Search for CBX BM100 at Device Startup
Select the check box to automatically search for a BM100 storage module when the
scanner is powered on.
Only available if BM100 included.
Enable Data Transmission
Select the check box to enabled Data Tx. If selected, the Aux Serial Port channel is
used by the scanner to transmit data and/or messages.
Heartbeat
Select Disable, Enable Unconditioned, or Enable Conditioned from the drop-down
list. This parameter is available when the Data TX parameter is checked. It enables/
disables the transmission of the Heartbeat message signaling that the device is still
active.
Disable: The Heartbeat message is not transmitted
Enable Unconditioned: The Heartbeat message is always transmitted, even if
communication is still active
Enable Conditioned: The Heartbeat message is transmitted only when there is
no communication
Heartbeat Settings
Heartbeat Timeout
Enter a time value in seconds to define the amount of time between two message
transmissions. If the input timeout expires and no transmission has occurred, the
Heartbeat message will be transmitted.
Heartbeat Message (max. 32 chars)
Click
to activate the Text Entry Tool and create heartbeat header text to signal
the beginning of the heartbeat message. Characters from NUL (00H) to ~ (7EH) can
be used. Click Submit to save your text to the origin window text field, or click
Cancel to return to origin window without transferring text.
The Heartbeat Message (header) string must be different from the Heartbeat
Terminator string.
Summary of Contents for DX8210
Page 1: ...DX8210 Reference Manual Omnidirectional Barcode Scanner ...
Page 31: ...Installation Reference Manual 19 Small Side Mounted L Bracket Options ...
Page 45: ...Tachometer Wiring to CBX510 Reference Manual 33 ...
Page 47: ...Tachometer Wiring to CBX510 Reference Manual 35 ...
Page 49: ...Digital Output Configuration to CBX510 Reference Manual 37 Unpowered Outputs Powered Outputs ...
Page 268: ...Barcode Scanning Features 256 DX8210 Barcode Scanner DX8210 2100 0 25 mm 10mil ...
Page 269: ...Reading Diagrams Reference Manual 257 DX8210 2100 0 30 mm 12mil ...
Page 270: ...Barcode Scanning Features 258 DX8210 Barcode Scanner DX8210 2100 0 38 mm 15mil ...
Page 271: ...Reading Diagrams Reference Manual 259 DX8210 2100 0 50 mm 20 mil ...
Page 272: ...Barcode Scanning Features 260 DX8210 Barcode Scanner DX8210 4100 0 38 mm 15 mil ...
Page 273: ...Reading Diagrams Reference Manual 261 DX8210 4100 0 50 mm 20 mil ...
Page 274: ...Barcode Scanning Features 262 DX8210 Barcode Scanner DX8210 4200 0 25 mm 10 mil ...
Page 275: ...Reading Diagrams Reference Manual 263 DX8210 4200 0 30 mm 12 mil ...
Page 297: ...Reference Manual 285 ...
Page 298: ......
Page 299: ......