INSTALLATION
13
2
2.3.5 RS232
Debug
The use of this connector is reserved for Service:
5
1
6
9
RS232 debug connector
RS232 Debug connector pinout
Pin Name
Function
2 TXD
Transmitted
data
3 RXD
Received
data
5 GND
Ground
2.3.6 Inputs
ENC is the encoder input and detects the conveyor speed.
EXT_TRIG is the presence sensor that, when active, tells the scanner that a pack is entering
the reading area.
All inputs are optocoupled and driven by a constant current generator; the command signal is
filtered through an anti-disturbance circuit which generates a configurable delay of about 5
ms or 500
µ
s.
The electrical features of the inputs are:
Maximum voltage 30 V
Maximum current 10 mA
Input NPN
Polarity Insensitive
Common Reference
EXTERNAL TRIGGER/
ENCODER
VS
A
Vext
B
GND
V
+ 5V
~
~
+
-
Ground
9
DX8200 Controller
EXTERNAL TRIGGER/
ENCODER
VS
B
Vext
A
GND
V
+ 5V
~
~
+
-
Ground
9
DX8200 Controller
EXTERNAL DEVICE
DX8200 Controller
IN3A
Vext
GND
V
+ 5V
~
~
+
-
EXTERNAL DEVICE
Vext
GND
V
IN4A
+ 5V
~
~
+
-
VS
INREF
9
Summary of Contents for DX8200