Enter/Exit Programming Mode
140
DSM0400 Fixed Mount Area Imager Bar Code Reader
Code 11 Set Length 1
This feature specifies one of the barcode lengths for Code 11. Length 1 is the
minimum label length if in
Mode, or the first fixed
length if in
Mode. Length includes the barcode’s check
and data characters. The length can be set from 2 to 50 characters. For more
detailed programming instructions see, "Set Length" on
.
provides some examples for setting Length 1.
Table 15. Code 11 Length 1 Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting (pad with
leading zeroes)
02 Characters
07 Characters
15 Characters
50 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODE 11 LENGTH 1 SETTING
4
Scan Two Characters From
‘0’ and ‘2’
‘0’ and ‘7’
‘1’ and ‘5’
‘5’ AND ‘0’
5
Scan ENTER/EXIT PROGRAMMING MODE
Select Code 11 Set Length 1 Setting
Make a mistake? Scan the CANCEL barcode to abort and
not save the entry string. You can then start again at the
beginning.
CANCEL
DEFAULT
01 = Length 1 is 1 Character
Summary of Contents for DSM0400
Page 1: ...DSM0400 Product Reference Guide Fixed Mount Area Imager Bar Code Reader ...
Page 12: ...Introduction 4 DSM0400 Fixed Mount Area Imager Bar Code Reader NOTES ...
Page 30: ...22 DSM0400 Fixed Mount Area Imager Bar Code Reader NOTES ...
Page 220: ...212 DSM0400 Fixed Mount Area Imager Bar Code Reader NOTES ...
Page 237: ...DSM0400 Dimensions Product Reference Guide 229 DSM0400 Dimensions ...
Page 242: ...Technical Specifications 234 DSM0400 Fixed Mount Area Imager Bar Code Reader NOTES ...
Page 248: ...Sample Bar Codes 240 DSM0400 Fixed Mount Area Imager Bar Code Reader NOTES ...
Page 250: ...Keypad 242 DSM0400 Fixed Mount Area Imager Bar Code Reader 6 7 8 9 ...