DS5100 REFERENCE MANUAL
136
A
OUTPUTS
Two general purpose optocoupled but polarity sensitive outputs are available on the 25-pin
D-sub connector.
The pinout is the following:
Pin
Name
Function
8
O1+
Configurable digital output 1 +
22
O1-
Configurable digital output 1 -
11
O2+
Configurable digital output 2 +
12
O2-
Configurable digital output 2 -
The electrical features of the two outputs are the following:
V
B
CE
B
max = 30 Vdc
40 mA continuous max.; 130 mA pulsed max.
USER INTERFACE
O+
8/11
22/12
O-
SCANNER
Vext 30 Vdc max.
C
E
Figure 78 - Open Emitter Output Connections
USER INTERFACE
O+
8/11
22/12
O-
SCANNER
Vext 30 Vdc max.
C
E
Figure 79 - Open Collector Output Connections