DS5100 REFERENCE MANUAL
20
2
2.1.1 Indicators
The five LEDs on the side of the scanner (
Figure A, B, C, D, E
, 7) indicate the following:
LED
Color
Description
READY
Green
This LED indicates the device is ready to operate. For Subzero
models this LED blinks during the warm-up phase.
GOOD
Green
This LED confirms successful reading.
TRIGGER
Yellow
This LED indicates the status of the reading phase. *
COM
Yellow
This LED indicates active communication on main serial port. **
STATUS
Red
This LED indicates a NO READ result.
* In On-Line mode the TRIGGER LED corresponds to the active reading phase signaled by the Presence Sensor.
In Automatic and Continuous modes the TRIGGER LED is always on indicating that the reader is ready to read a
code.
** When connected to a Fieldbus network through the CBX500, the COM LED is always active, even in the
absence of data transmission, because of polling activity on the Fieldbus network.
During the reader startup (reset or restart phase), all the LEDs blink for one second.
PWR (blue)
This LED indicates that the reader is connected to the power
supply.
ETH (yellow)
This LED indicates connection to the on-board Ethernet or
Profinet-IO network.
2.2 ID-NET
The ID-NET network is a built-in high-speed interface dedicated for
high-speed scanner interconnection. ID-NET is in addition to the
Main and Auxiliary serial interfaces.
The following network configurations are available:
ID-NET Synchronized:
Single station
– multiple scanners
ID-NET interface allows local connection of
multiple scanners reading different sides of
the same target. All scanners share a
single
presence
sensor
and
activate/deactivate simultaneously.
At the end of each reading phase a single
data message is transmitted to the host.
Thanks to ID-NET, data communication
among scanners is highly efficient so that
an immediate result will be available.
Summary of Contents for DS5100
Page 1: ......
Page 30: ...DS5100 REFERENCE MANUAL 14 1 b Digital Outputs configuration c Hardware interface selection...
Page 62: ...DS5100 REFERENCE MANUAL 46 3 Figure 18 DS5100 OM Serial Model Overall Dimensions...
Page 78: ...DS5100 REFERENCE MANUAL 62 4 Figure 38 ID NET Network Connections with isolated power blocks...
Page 97: ...TYPICAL LAYOUTS 81 5 7 Double click on the DS5100 scanner to configure it...
Page 163: ...147 X X PRESS Human Machine Interface 23...
Page 164: ......