![Datalogic DS2100N Reference Manual Download Page 71](http://html.mh-extra.com/html/datalogic/ds2100n/ds2100n_reference-manual_511867071.webp)
25-PIN CABLE ELECTRICAL CONNECTIONS
61
5
5.3.2 ID-NET™
Response
Time
The following figure shows the response time of the ID-NET™ network. This time is defined
as the period between the Trigger activation and the beginning of data transmission to the
Host.
Max ID-NET™ Response Time
240
220
200
180
160
140
120
100
80
60
40
20
0
Response Time (ms)
Number of Nodes
500 kbps
250 kbps
125 kbps
0 1 2 3 4 5
6
7
8
9
10
11
12
13
14
15
16
Figure 69 – ID-NET™ Response Time
CONDITIONS:
ID-NET™ M/S Synchronized layout
message length = 50 bytes per node