6.2.2 Cleaning the of the DM3610 Dimensioner
s’ Exit Windows
WARNING:
Shut down the DM3610 before performing this maintenance
task. Do not stare into the DM3610
’s exit window at the laser light. Avoid
direct eye exposure. The laser light level does not constitute a health
hazard, however staring at the laser light for prolonged periods could result
in eye damage.
CAUTION:
Never apply cleaning solution directly to the exit window.
Always apply the solution to a cloth, and then the cloth to the window. Do
not use any chemical on the DM3610 that is unsafe for plastics, such as
benzene, acetone, or similar products.
The exit window cleaning procedure may be performed without removing the reader from the
mounting structure if it is possible to do so.
1. Turn off the DM3610 by disconnecting the power source.
2. Follow the exterior cleaning procedure before cleaning the exit window
3. Check the exit window surface for any dust, dirt, or smudges. If the window needs to
be cleaned, proceed to Step 4.
4. Make a solution of seven parts denatured alcohol and three parts water.
5. Apply the cleaning solution to a cotton swab or lint-free cloth.
6. Apply the cleaning solution to the exit window.
7. Remove any streaks or remaining moisture from the exit window with a dry, soft, lint-
free cloth or lens paper.
8. Verify DM3610 operation.
Figure 66: DM3610 Exit Window Location
EXIT WINDOW