![Datalogic Compact 2D Reader Matrix-2000 Reference Manual Download Page 53](http://html.mh-extra.com/html/datalogic/compact-2d-reader-matrix-2000/compact-2d-reader-matrix-2000_reference-manual_511837053.webp)
19-PIN CONNECTOR ELECTRICAL CONNECTIONS
5
5 MATRIX-2000™ CONNECTOR ELECTRICAL CONNECTIONS
5.1 DB25-PIN CONNECTOR
The Matrix-2000
™
reader is equipped with a 25-pin male D-Sub connector for connection to
the power supply and input/output signals. The details of the connector pins are indicated in
the following table:
13
25
14
1
Figure 61 - 25-pin male D-Sub Connector
19-pin M16 male connector pinout
Pin Name
Function
9, 13
Vdc
Power supply input v
23, 25
GND
Power supply input voltage -
1 CHASSIS
Cable shield internally connected by capacitor to the
chassis
18
I1A
External Trigger A (polarity insensitive)
19
I1B
External Trigger B (polarity insensitive)
6
I2A
Input 2 A (polarity insensitive)
10
I2B
Input 2 B (polarity insensitive)
8
O1+
Output 1 +
22
O1-
Output 1 -
11
O2+
Output 2 +
12
O2-
Output 2 -
16
O3+
Output 3 +
17
O3-
Output 3 -
20
RX
Auxiliary RS232 RX (referred to GND)
21
TX
Auxiliary RS232 TX (referred to GND)
14, 15, 24
NC
Not connected
Pin Name RS232
RS485
Full-Duplex
RS485
Half-Duplex
2 TX
TX+
RTX+
3 RX
*
RX+
4 RTS
TX-
RTX-
5
MAIN
INTERFACE
(SW
SELECTABLE)
CTS
*
RX-
7
GND_ISO GND_ISO
GND_ISO
* Do not leave floating, see par. 5.5.2 for connection details.
In order to meet EMC requirements:
•
connect the reader chassis to the plant earth ground by means of a flat copper braid
shorter than 100 mm;
•
connect the main interface cable shield to pin 1 of the 25-pin connector;
•
use two clip-on ferrite sleeves (type Stewart 28A2029-0A0 or equivalent) on the main
interface cable near the reader 25-pin connector;
•
connect the Ethernet interface cable shield to reader chassis (for Matrix-21XX only)
43