Timeout: Enter Standby State
Enter/Exit Programming Mode
Product Reference Guide
63
Timeout: Enter Standby State
Specifies the standby timeout in minutes.
Upon having been in Low Power state (see
) for this period of time, the scanner will
enter a Standby state where the laser and motor are turned off and the scanner is not able to
decode a label.
NOTE
When this feature is set as Disabled, the scanner will never enter this state.
The standby timer starts only after the low power timeout has elapsed.
If you wish the scanner motor and laser to completely power off after 10 minutes,
you must be sure that the timeout periods for low power and standby total 10
minutes.
To exit this state, press the button on the top of the scanner.
NOTE
Enter Standby Timeout = Disabled
Enter Standby Timeout = 1 Minute
Enter Standby Timeout = 2 Minutes
Enter Standby Timeout = 3 Minutes
DEFAULT
Enter Standby Timeout = 5 Minutes
If the feature
has been set to “Disabled,” the button
will not trigger single line scanning and the
scanner will never enter low
power state and standby state.
$CSBTO00
$CSBTO01
$CSBTO02
$CSBTO03
$CSBTO05
Summary of Contents for Cobalto C05300
Page 12: ...Contents x Cobalto CO5300 Scanner NOTES ...
Page 26: ...Setup 14 Cobalto CO5300 Scanner NOTES ...
Page 44: ...Enter Exit Programming Mode Enable Character 32 Cobalto CO5300 Scanner NOTES ...
Page 228: ...Enter Exit Programming Mode Plessey 216 Cobalto CO5300 Scanner NOTES ...
Page 254: ...References 242 Cobalto CO5300 Scanner NOTES ...
Page 260: ...Technical Specifications 248 Cobalto CO5300 Scanner NOTES ...
Page 274: ...Standard Defaults 262 Cobalto CO5300 Scanner NOTES ...
Page 278: ...Sample Bar Codes 266 Cobalto CO5300 Scanner NOTES ...
Page 280: ...Keypad 268 Cobalto CO5300 Scanner 5 6 7 8 9 A B C ...
Page 281: ...Product Reference Guide 269 D E F ...