Good Read LED Duration
This feature specifies the amount of time that the Good Read LED remains on following a good
read. The good read LED on time can be set within a range of 0.1 to 25.5 seconds in 100ms
increments.
Follow these instructions to set this feature:
1.
Determine the desired setting in milliseconds. A setting of 0 means that the good read
LED stays on until the next time the trigger is pulled.
2.
Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with
leading zeroes to yield three digits. For example: 0 = 000, 5 = 000, 20 = 020, etc.
3.
Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming Mode.
4.
Scan the bar code: SELECT GOOD READ LED DURATION SETTING.
5.
Scan the appropriate three digits from the keypad in
representing the
duration which was determined in the steps above. You will hear a two-beep indication
after the last character.
NOTE
If you make a mistake before the last character, scan the CANCEL bar code to
abort and not save the entry string. You can then start again at the begin-
ning.
6.
Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See the table below for examples of how to set this feature.
Table 19. Good Read LED Duration Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
Good Read LED
stays on until
next trigger pull
(00)
200ms
1500ms (1.5
sec.)
2500ms (2.5 sec.)
2
Divide by 100 (and pad with
leading zeroes)
000
002
015
025
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT GOOD READ LED DURATION SETTING
5
Scan Three Characters From
‘0’, ‘0’ and ‘0’
‘0’, ‘0’ and ‘2’
‘0’, ‘1’ and ‘5’
‘0’, ‘2’ and ‘5’
6
Scan ENTER/EXIT PROGRAMMING MODE
Summary of Contents for Cobalto C05300
Page 12: ...Contents x Cobalto CO5300 Scanner NOTES ...
Page 26: ...Setup 14 Cobalto CO5300 Scanner NOTES ...
Page 44: ...Enter Exit Programming Mode Enable Character 32 Cobalto CO5300 Scanner NOTES ...
Page 228: ...Enter Exit Programming Mode Plessey 216 Cobalto CO5300 Scanner NOTES ...
Page 254: ...References 242 Cobalto CO5300 Scanner NOTES ...
Page 260: ...Technical Specifications 248 Cobalto CO5300 Scanner NOTES ...
Page 274: ...Standard Defaults 262 Cobalto CO5300 Scanner NOTES ...
Page 278: ...Sample Bar Codes 266 Cobalto CO5300 Scanner NOTES ...
Page 280: ...Keypad 268 Cobalto CO5300 Scanner 5 6 7 8 9 A B C ...
Page 281: ...Product Reference Guide 269 D E F ...