Datalogic BM100 Instruction Manual Download Page 1

 

 
 

BM100 

BACKUP MODULE 

INSTRUCTION MANUAL 

 
 
 
 

 

 

Figure 1 General View 

 

 

Backup/Restore button 

BM150 Display connector 

Write Protection Lock 

ID-NET™ Baudrate Switch 

6

Backup/Restore Indicator LEDs

5

Network Address Switches 

7

Network Type Switch 

 

 
 

DESCRIPTION 

 
The BM100 Backup Module is an accessory for the CBX series 
connection boxes. It provides the following functions: 
 

• 

Backup and Restore 
Complete Configuration and Environmental parameter storage 
for network and reading devices. Includes write protection. 

 

• 

Network Address Selection 
Hardware Address selection for Fieldbus or ID-NET™ Slave 
devices (overrides software configuration). 

 

• 

Network Type Selection 
Selection of Fieldbus or ID-NET™ Slave type networking 
depending on application and installed accessories. 

 

• 

BM150 Accessory Display Connection (CBX500 only) 
Connection to flat cable for BM150 Display and Keypad. 

 
 
 
 
 
 

821001400 

INSTALLATION 

 

 

CAUTION 

Power must be off during this operation. 

 
The BM100 can easily be installed into the CBX100 or CBX500 
connection box by aligning it over its corresponding connector and 
pushing down until correctly seated. When closed, the plastic 
support inside the CBX cover holds the module in place. 
 

 

 

 

 
 

 

 

 

 

Figure 2 – BM100 Mounting 

BACKUP AND RESTORE PROCEDURE 

 
The backup and restore functions are valid for any application 
layout type (point-to-point, network, etc.) using either CBX100 or 
CBX500 connection boxes. 
 
If it ever becomes necessary to replace the reading device it can 
be quickly configured through the restore procedure. 
 
BM100 always provides complete backup and restore functions 
(Configuration and Environmental parameters) and cannot be 
interrupted once started (LED quickly blinking). 

• 

For Network nodes, the backup module of the Master saves 
the configuration of all the reading devices in the network, 
Master and all individual Slaves. 

• 

For single reading device stations or for Slaves, the backup 
module saves the configuration of the specific connected 
reading device. 

 
These functions are cyclical every 3 seconds: 

Backup

 

Restore

 

No Action

 

 
 
To perform 

Backup

 
1.  Make sure the Write Protection switch is unlocked. 

2.  Press and hold the Backup & Restore button for approximately 

3 seconds. The green Backup LED (B) lights up. 

3.  Release the button. The green Backup LED (B) blinks slowly. 

4.  Press the Backup & Restore button again while the LED is 

blinking. The green Backup LED (B) blinks quickly indicating 
the backup procedure is active. When the LED turns off the 
procedure is complete. 

5.  Set the Write Protection switch to locked. 
 
 
To perform 

Restore

 
1.  Press and hold the Backup & Restore button for approximately 

6 seconds. The yellow Restore LED (R) lights up. 

2.  Release the button. The yellow Restore LED (R) blinks slowly. 

3.  Press the Backup & Restore button again while the LED is 

blinking. The yellow Restore LED (R) blinks quickly indicating 
the restore procedure is active. When the LED turns off the 
procedure is complete. 

 
 
To exit without performing Backup or Restore procedures, release 
the button while both LEDs are off (

No Action

), or wait for about 3 

seconds (timeout) after the slow blinking LED. 

6