USE AND OPERATION
64
AREX™ 400
Sequence Using Command Box
Turn ON the main power supply switch in the back panel of the control rack. The laser
marker turns on and goes in booting-up state. During booting up state, the status LED
on the control rack and the status LED on the scan head blink green.
Wait until booting-up has ended: the status LED on the control rack and the status LED
on the scan head are steady green. The laser marker is in WAIT FOR START state.
Figure 7: Wait for start state
Set the Command box input signals as in the table below:
EXT_KEY
EXT_ENABLE_A
EXT_ENABLE_B
HIGH
LOW
LOW
Steady
The status LED on the control rack and the status LED on the scan head are steady
orange. The laser marker is in STANDBY SHUTTER CLOSED state.
Figure 8: Standby Shutter closed state
Set the Command box input signals as in the table below:
EXT_KEY
EXT_ENABLE_A
EXT_ENABLE_B
HIGH
HIGH
HIGH
Steady
CAUTION
Controlling the laser marker states using the Command Box connector on
the control rack back panel requires that the Key Selector is set to fixed
position
LASER_ON
.
STATE
COMMAND BOX INPUT
STATE
KEY
SELECTOR
STATUS LED
STANDBY SHUTTER
CLOSED
STATE
COMMAND BOX INPUT
STATE
KEY
SELECTOR
STATUS LED
READY*