AREX
TM
30W – 50W
14
1
The marking system can be fitted inside a special rack cabinet equipped with special support shoulders and
handles, available on request. The figure below shows the mounting points for mounting in rack (rack
handles available as accessory):
Figure 6: Fixing points on shrug rack (cabinet assembly).
NOTE:
In order to prevent marking distortions, install a vibrometer on the base of the piece to be marked
and check for the absence of vibrations during the marking process.
NOTE:
It is recommended to install the resonator on a micrometer positioning Z-axis system!
The Scan Head must be fixed to a suitable base (not supplied by Datalogic) using the four M5 threaded
holes and the two slotted seats:
Figure 7: Fixing points on Scan Head (vertical mount).
The Scan Head unit, just like the control rack, must be safely positioned and fixed to a stable surface,
vibration-free. The Scan Head can be fixed either vertically or horizontally. In order to prevent marking
distortions, avoid any vibration between Scan Head and piece to be marked.
WARNING!
It is very important to secure the laser system before you start marking the piece since improper
securing or positioning may cause serious damage.
Do not secure the marking system in a way other than the one described in the figure.
Summary of Contents for Arex 30W
Page 1: ...USER S MANUAL ArexTM 30W 50W ...
Page 92: ...92 APPENDIX G MECHANICAL DRAWINGS ...
Page 93: ...93 NOTE Please refer to Datalogic website for detailed drawings ...
Page 96: ......