DataVS1
Series
Instruction
Manual
30
It is also possible to set a delayed image acquisition compared to the trigger signal received for both
hardware triggers. To set the delay value, simply use the slider found at the bottom of the screen using
the
RIGHT/LEFT ARROW
buttons.
Example:
The image acquisition is delayed by 150 ms compared to the rising edge of the trigger signal.
6.3.
Load/Save
The term load/save menu identifies the control panel used to manage the databank areas available
on the sensor.
NOTE:
The load/save menu is the only access point to the FLASH memory installed on the sensor.
During all configuration steps in fact, a RAM type memory is used which is reset each time the device
is powered down. Therefore, when the current settings are modified, and you wish to render them
permanent, it is necessary to save the inspection tool using the load/save menu.
The 8 memory slots available on the sensor are displayed at the top of the screen. Each bank can
take on three different status modes (identified by 3 different colours):
Current bank (white)
Current memory slot
Free bank (green)
Free bank
Full bank (yellow)
Memory slot full. If you save a new inspection to this slot, it will overwrite the previous
version.