![DataLocker Sentry K350 User Manual Download Page 13](http://html1.mh-extra.com/html/datalocker/sentry-k350/sentry-k350_user-manual_511758013.webp)
Sentry K350 hardware encrypted USB flash drive - User Guide
Auto-Lock Time
Available for ADMIN/USER
This feature is disabled by default but can be enabled by the administrator and the user. Auto-lock
will disconnect the drive once it is idle (i.e. zero activity) for the configured amount of time. The
amount of idle time required to time out the device is configurable from 10 to 720 minutes.
To enable auto-lock, follow these steps:
1. Select
Auto-Lock Time
from the Configuration Menu, confirm with Enter-button.
2. Confirm Enable-selection with Enter-button.
3. Enter the desired number of minutes the device can remain unlocked and idle, confirm with
Enter-button. The device goes back to the Configuration menu after the confirmation.
Read-Only Mode
Available for ADMIN
Administrators can select the
Read-Only Mode
to globally enforce the K350 to always unlock in
read-only mode. Enabling this option will also enforce read-only access for the User profile (if the
user profile is enabled). Once the
Read-Only Mode
is enabled, data can only be read from the
K350 and no data can be written or modified.
To enable
Read-Only Mode
, follow these steps:
1. Select
Read-Only Mode
feature from the Configuration Menu, confirm with Enter.
2. Confirm
Enable
-selection with Enter-button. The device goes back to the Configuration menu
after the confirmation.
NOTE:
The administrator and the user can each set Read-Only Mode for a single login by select-
ing/confirming Read-Only Mode in the Connect Selection Menu after entering their password. The
Read-Only Mode
in the Configuration Menu will enforce this functionality for every login.
Keypad Preference
Available for ADMIN
Administrators can select the
Keypad Preference
for the device passwords. Having alphabetical
first can positively lead to the users selecting more complex passwords, rather than a numbers
based password.
To select
Keypad Preference
, follow these steps:
1. Select
Keypad Preference
feature from the Configuration Menu, confirm with Enter.
2. Confirm
Enable
-selection with Enter-button to have the buttons input lead with the alphabet-
ical characters, such as ABC2 rather than the defaul 2ABC.
© 2021 DataLocker Inc. All rights reserved.
13