The DKM-407 is a DIN rail mounted precision 
unit allowing measurement and monitoring of 
AC parameters of a distribution panel. 

The unit is supplied between L1 and Neutral 
terminals. Thanks to the supply range of 85-
305V, it is not affected by voltage fluctuations 
and is capable of operating in any network. 

The unit features an 32-bit ARM core 
microcontroller. With a sampling rate of 
4096s/s it reaches 0.5% precision. 

The isolated RS-485 Modbus RTU port is not 
affected by ground potential differences. 

Program parameters may be uploaded from 
PC.  

 

  Electrical equipment should be installed 

only by qualified specialist. No responsibility 
is assured by the manufacturer or any of its 
subsidiaries for any consequences resulting 
from the non-compliance to these 
instructions. 

  Check the unit for cracks and damages due 

to transportation. Do not install damaged 
equipment. 

  Do not open the unit. There is no 

serviceable parts inside. 

  Fuses of fast type (FF) with a maximum 

rating of 6A must be connected to phase 
voltage inputs, in close proximity of the unit. 

  Disconnect all power before working on 

equipment. 

  When the unit is connected to the network 

do not touch terminals. 

  Short circuit terminals of unused current 

transformers. 

  Any electrical parameter applied to the 

device must be in the range specified in the 
user manual. 

  Verify correct terminal connections before 

applying power. 

 

 

 

 

 

Before installation: 

 Read the user manual carefully, determine 

the correct connection diagram. 

 Install the unit to the DIN rail. 

 Make electrical connections with plugs 

removed from sockets, then place plugs to 
their sockets.

 

 Note that the power supply and measuring 

circuits use common neutral.

 

Below conditions may damage the device: 

 Incorrect connections. 

 Incorrect power supply voltage. 

 Voltage at measuring terminals beyond 

specified range. 

 Current at measuring terminals beyond 

specified range. 

 Connecting or removing data terminals 

when the unit is powered-up. 

 Overload or short circuit at relay outputs 

 Voltage applied to digital inputs over 

specified range. 

 High voltage applied to communication port. 

Below conditions may cause abnormal 
operation: 

 Power supply voltage below minimum 

acceptable level. 

 Power supply frequency out of limits 

 Phase order of voltage inputs not correct. 

 Current transformers not matching related 

phases. 

 Current transformer polarity incorrect. 

 

 

 

 

   

   

 

 

 

Detailed user manual of this product 

may be downloaded at: 

www.datakom.com.tr 

 

INSTALLATION

 

DKM-407 DIN RAIL TYPE NETWORK 

ANALYZER

 

 

 

SAFETY NOTICE  

Failure to follow below 
instructions will result in 
death or serious injury 

 