This product depends on the previous installations against short-circuit and circuit
overload.
Linking both cables to a single circuit break is not recommended, as this will affect the
power redundancy schematics.
3.2.
INSTALLING THE DM4610 CHASSIS
The DM4610 chassis has lateral brackets with depth adjustment, facilitating installation in different 19-inch
rack configuration, the space required is 1U. It is possible to adjust the lateral brackets to two depths (0 or 73
mm). The standard factory configuration is 0 mm. The following figure shows the assembly of the lateral
brackets in the two possible positions.
DM4610 with side tab at the 0 mm
DM4610 with side tab at the 73 mm
Figure 4 -
DM4610 with and without side tab
If necessary, the installer must remove the lateral screws, adjusting the brackets to a depth of 73 mm. This
mounting brackets configuration positions the chassis deeper inside the rack.
Each bracket is fixed to the chassis by a set of six screws. In the case of changing the position (0 or 73 mm),
the screws will be fixed in the same position they were, and the lateral brackets will advance to the second
attachment position.
Once the position of the lateral brackets has been determined, choose the position inside the rack where the
DM4610 should be placed.
Leave at least 1U height empty at the top and bottom of the DM4610, to facilitate the passage of cables and
see the lights indicators of interfaces.