Device Programming and Setup via GUI Interface
Connecting to the GUI Interface
Factory Default IP: 192.168.1.9
◊
Connect an Ethernet cable directly (
no Cross Over cable required
) to the UTILITY Port on the rear panel of the
encoder or connect the Ethernet cable to an Ethernet switch. Connect an Ethernet Cable to your PC/Laptop.
◊
Modify your PC/Laptop IP address to 192.168.1.11.
◊
Enter ‘192.168.1.9’ into your web browser.
◊
Enter GUI and make required device changes.
◊
Save all changes as required, upload and reboot changes.
◊
Verify parameters then end web session.
Overview Page
Overview Page will provide an overall system status of the DT-ATSC-IP-8 Converter state: Signal Strength and Signal
Quality.
System Parsing / Response Time:
The initial System Parsing time will range from 3-4 minutes on average as the system identifies and
populates the required parameters.
As the user navigates the device's menu note that a small delay may occur in populating the data on the screen as the
system is constantly performing system parsing and system housekeeping functions.