Chapter 7
56
Performing a Single-Value Analog Output Operation
To verify that the module can output a single analog output value,
perform the following steps:
1.
Connect an oscilloscope or voltmeter to DAC0 on the DT9822
function module. Refer to
for an example of how to
connect analog output signals.
2.
Click the Control menu.
3.
Click Single Analog Output.
4.
Select the appropriate DT9820 Series function module from the
Board list box.
Note:
Once you select the function module, the LED on the
module turns green.
5.
In the Channel list box, select analog output channel 0.
6.
In the Range list box, select the output range of DAC0.
The default is ±5 V.
7.
Enter an output value, or use the slider to select a value to output
from DAC0.
8.
Click Send to output a single value from DAC0.
The value that is output is displayed on the screen in both text and
graphical form.