Maintenance ■ Troubleshooting
- 138 -
Data I/O ■ 096-0465-001C
Air Pressure Problems
Lamp Color
Error Messages
Possible Resolution
Red
•
There is no main air
pressure.
•
Make sure that the main air switch on the
Power Panel is in the ON position.
•
Check that the air regulator on the Power
Panel displays within the acceptable range:
PSV5000 Specifications on page 1-9.
If not:
• Check your shop air pressure.
• Shut down and replace the filter. See
Replacing the Input Air Pressure
on page 107.
The digital display on the regulator will be
green when air pressure is within the correct
range and red when it is out of range. The
regulator has been set at the factory and is
not adjustable.
Red
•
There is no (or low)
vacuum on the PNP
probe.
•
Check that the probe is not loose and that
the O-Ring is not destroyed or leaking.
See
Pick and Place Probe
on page 103.
•
Determine if the PNP head probe is clogged.
Clean if necessary. Refer to Removing and
Installing a Probe in the PSV5000 Operator’s
Manual.
•
Check the probe vacuum and Blow-off
solenoids; see
Adjusting the Vacuum
Generator Sensors
on page 105.
•
Clean the vacuum generator filters and
silencers; see
Vacuum Generator Filters and
Silencers on page
Summary of Contents for PSV5000
Page 12: ......
Page 36: ......
Page 160: ......
Page 161: ...Electrical Schematics for PSV5000 and Equipment ...
Page 162: ......
Page 163: ......
Page 164: ......
Page 165: ......
Page 166: ......
Page 167: ......
Page 168: ......
Page 169: ......
Page 170: ......
Page 171: ......
Page 172: ......
Page 173: ......
Page 174: ......
Page 175: ......
Page 176: ...PROGRAMMABLE MEDIA EXPERTS ...