Maintenance ■ Pick and Place Probe
- 106 -
Data I/O ■ 096-0465-001C
completing the Z-Axis adjustment does not reduce or eliminate subsequent
pick errors, complete the vacuum sensor adjustments described here.
Vacuum sensors on the PSV5000 System are adjustable. The I/O
Interface window displays a list of the sensors in the PSV5000 System
and the status of each sensor.
Note:
The number of sensors on the PSV5000 System depends on the
options installed.
To view the status of sensors at the main CH700 Setup window, click
System > Misc. I/O.
Figure 62:
The I/O Interface window reports sensor status and
allows switching options on or off.
T
O
A
DJUST
P
ROBE
V
ACUUM
G
ENERATOR
S
ENSORS
:
1.
Finish a job.
2.
At the Gantry window, move the PNP head to the Park position.
3.
Close the Gantry window and at the System window click Misc. I/O.
4.
At the I/O Interface tab, click the Vacuum toggle ON and the
Blow-off toggle OFF. Refer to the figure above.
5.
Open the rear safety door.
6.
With a device or clean finger, plug probe tip 1 and ensure the green
generator lamp comes on. See the figure below.