Installation
42
System Hardware Guide
Installation
Note
Illustrations of Data Domain system front panels in this document do not include the
protective bezel.
To install a DD120 Data Domain system:
1.
Complete all site preparation as described in “Power and Weight Specifications” on page 18.
2.
Set up the rack-mounting hardware. See the slide rail and rack installation instructions in the
slide rail package that is in the DD120 shipping box.
3.
Attach the rack handles to each side of the DD120 face plate.
4.
To use DHCP with Ethernet interfaces:
-
Configure the DHCP server with the appropriate Data Domain system information.
-
Provide DHCP information for at least one interface.
The alternative to DHCP is to use a serial console or a keyboard and monitor. Use a serial
console or a monitor and keyboard if you are not using an Ethernet interface for configuration.
5.
Mount the DD120 in a 1U space in a 19-inch, four-post rack using the following procedure.
Use the slide rails provided. Any other means of mounting the Data Domain system must be
rated for at least 23 pounds (11 kilograms).
Do NOT install a DD120 in a two-post rack.
a.
Attach a rack handle to each side of the DD120 face plate. See Figure 12. The rack
handles and screws are in the plastic bag of miscellaneous parts.
Figure 12: Rack handles
b.
Open the slide rails package that ships with the Data Domain system.
c.
Use the slide rail instructions to mount the inner rails onto the Data Domain system and
mount the outer rails onto the rack.