DART Controls DM4000 Series Instruction Manual Download Page 1

DM4000 CONTR

OL SERIES

LTDM4 (IM-DM4-0501)

P.O. Box 10
5000 W. 106th Street
Zionsville, Indiana 46077

Phone (317) 873-5211

Fax (317) 873-1105

www.dartcontrols.com

Instruction Manual

Low Voltage DC Brushless Control

CONTROLS

Summary of Contents for DM4000 Series

Page 1: ... CONTROL SERIES LTDM4 IM DM4 0501 P O Box 10 5000 W 106th Street Zionsville Indiana 46077 Phone 317 873 5211 Fax 317 873 1105 www dartcontrols com Instruction Manual Low Voltage DC Brushless Control CONTROLS ...

Page 2: ...wer disconnect point is out of sight lock it in disconnected position and tag to prevent unexpected application of power Only a qualified electrician or service personnel should perform any electrical troubleshooting or maintenance At no time should circuit continuity be checked by shorting terminals with a screwdriver or other metal device INTRODUCTION The Dart DM4000 Series is available in two b...

Page 3: ... SIDE OF GASKET FACING THE CUSTOMER MOUNTING PANEL CUSTOMER MOUNTING PANEL HOLE CUT OUT FOR CONTROL HOUSING APPROXIMATELY 3 675 WIDE BY 1 770 HIGH DM4000 SERIES CONTROL DM4000 SERIES FACEPLATE ASSEMBLY 2 CUT OUT MOUNTING DIMENSIONS STEP 1 Remove two screws securing red lens STEP 2 Mount the DM4000 series meter into the panel cut out Note diagram for cut out dimensions shown below Allowance for eas...

Page 4: ...g or noisy environments a shielded cable is recommended Connect the shield to the common terminal on the ASP10 leaving the shield on the PU E end floating No other mounting screws are necessary as the cord will keep the unit from rotating The PU E gives a high signal when the north pole of the magnetic disk crosses the hall effect The signal is switched low when the south pole crosses the same res...

Page 5: ...LD PROGRAMMING FORMULA MULTIPLIER TRIMPOT DISPLAY PANEL TIMER SWITCHES DM4000 FRONT VIEW WITHOUT LENS Example Find R We want the meter to display 15 feet per minute at a shaft speed of 1000 RPM Therefore R 15 1000 0 015 Example Use Programming Formula for the DM4004 A motor drives an auger which moves material and we want displayed lbs hr of material moved We know that at 990 RPM we move 435 lbs o...

Page 6: ... 226 then S8 128 S7 64 S6 32 S2 2 226 STEP 6 Set the Multiplier trimpot using the M value determined in STEPS 3 4 and 5 DECIMAL POINT SELECTION All decimal points are illuminated and are covered with black adhesive backed dots If a decimal point is needed remove dot to illuminate the desired decimal point COMMONLY ASKED QUESTIONS Q Can the DM4000 Series be used above 9 999 RPM A Yes there will be ...

Page 7: ...etween inputs A Yes On the PU E pick up switch the SIG wire and leave the COM and V connected to each pick up do not exceed nine PU E pick ups per DM unit Q Can I tie the DM4000 Series to a computer A No there are no computer outputs available from the DM4000 Series Q What is the update time A This varies with the programming of the S value setting which ranges from 0167 through 4 25 seconds The D...