Page 27 of 30 

 

 

Picture 

Description 

Order Code 

 

 

Autoclavable handle 

 

 

CS6165 

 

 

Head thumb Screw 

 

 

CS6143 

 

 

Wall bracket thumb 

screw 

 

D16247 

 

 

12V Plug-top 

transformer 

(non-mobile) 

 

 

DRK4148 

 

 

12V PSU and 3m IEC 

Cable Kit  

(mobile) 

 

 
 

DRK4176 

 
 

 

 
 

For any SPARE PARTS or TECHNICAL ISSUES phone DARAY’S Service Delivery Team on: 

+44 (0) 800 878 9864 

Opening times

 

9am–5pm Monday to Thursday (excluding bank holidays) 

9am-2:30pm on Friday

 

 

Or email: 

 

[email protected]

 

 

IF THE LIGHT WAS ORIGINALLY PURCHASED THROUGH A DISTRIBUTOR CONTACT THEM IN 

THE FIRST INSTANCE FOR A RESOLUTION 

Please contact DARAY for help with any problems that the distributor cannot solve. 

 

 

Summary of Contents for X740

Page 1: ...X740 LED Examination Light Operating Installation Manual QAM X740 0519 4...

Page 2: ...Page 1 of 30...

Page 3: ...d Installation 15 4 1 4 X740LE2 Placement and Installation 15 4 1 5 X740LE3 Placement and Installation 16 4 1 6 X740LE4 Placement and Installation 16 4 2 Rail mounted version X740LR 18 4 3 Desk mounte...

Page 4: ...llow accurate and stable positioning of the light patch The light comprises 3 parts light head and articulated arm system power supply module and the mount of choice The rigid spring balanced arm allo...

Page 5: ...owing Models are supported in this Manual X740LW X740 LED Wall Mounted Light X740LR X740 LED Rail Mounted Light X740LD X740 LED Desk Mounted Light X740LDS X740 LED Weighted Desk Stand Light X740LDFM X...

Page 6: ...000K 500 Colour Rendering Index CRI 95 Colour Rendering R9 95 Light Field Diameter D50 0 5m 60mm 0 75m 90mm 1 0m 120mm Light Field Diameter D10 0 5m 110mm 0 75m 150mm 1 0m 200mm Number of LED s 4 Powe...

Page 7: ...op transformer 1 8m 1 12V Plug top transformer 1 8m 1 Desk Clamp Fixed Desk Mount Desk Stand 1 Wall bracket fixings 1 Light head and rigid arm system 1 Thumb Screw for Wall Mount 1 Microfibre cloth 1...

Page 8: ...rigid arm system 1 User Manual Microfibre cloth 1 User Manual 1 2 2 Pre Start Checks Please check that the power cable is without visible damage harsh folds knots or cuts in the rubberised coating Wh...

Page 9: ...Page 8 of 30 3 Operation 3 1 Range of Motion The full range of motion between the X740 Range varies This is an image depicting the range of motion on a standard wall mount fitting...

Page 10: ...mperature Press the power button to power ON or OFF Press and hold the plus or minus buttons to adjust the intensity It takes approximately 5 seconds to switch between the highest and lowest settings...

Page 11: ...an adjustment knob on the side of the arm near the head This also controls the forward and backward motion of the head itself Loosening this thumb screw will allow you to position the light head up or...

Page 12: ...atible versions X740LW X740LE1 X740LE2 X740LE3 X740LE4 The wall bracket needs to be true on the vertical plane PIVOTW2 supplied with X740LW PIVOTW6 supplied with X740LE4 PIVOTW5 supplied with X740LE3...

Page 13: ...ical procedures the light will be used for If in doubt consult the end user or DARAY When installing the bracket take consideration of where you want the light head to sit when in its lowest position...

Page 14: ...ring in mind the final position of the light head required to project its light patch where it will be needed We recommend 850 1100mm from the floor to the underside of the bracket dependent on couch...

Page 15: ...light on See page 9 Check arm and head for smooth and correct movement Your new DARAY light is now ready for use To gain full support of our warranty please fill in our warranty web form or contact DA...

Page 16: ...s version includes our PIVOTW4 spreader plate wall mounting bracket Suitable for fixing to all wall types including brickwork A separate power supply is included Mark on the wall the selected location...

Page 17: ...unting bracket Fit front bracket and rear plate to pre drilled panel Fit light spigot into bracket and pass cable through to the rear of panel Make electrical connection to transformer Fit pre drilled...

Page 18: ...s from the wall mounting box with the hex wrench provided Feed the mains supply via the cable entry hole on the back plate Connect the mains supply to the fused terminal block found on the back plate...

Page 19: ...il and fit the light to the rail The light can be moved along the rail by slackening the clamp slightly and not sufficiently to allow the light to become detached from the rail 4 3 Desk mounted versio...

Page 20: ...e upstand push down with a firm pressure until the upstand is fully inserted NOTE Insertion of upstand may be very tight and may require the use of a wooden or rubber mallet to tap the upstand downwar...

Page 21: ...e into the black power supply attached to the base upstand The light can now be tested by connecting the DC jacks between the power supply and the light and applying power Press the switch on the head...

Page 22: ...mobile version of this light please use the extension cable provided NOTE Charging time can take up to 8 hours depending on how depleted the battery is 2 If you need to use the light on battery power...

Page 23: ...ge Remove arm clean spigot and re grease as necessary Check all electrical connections are sound and that there is no visible cable wear All fixings to be checked and be of sound construction 5 2 Safe...

Page 24: ...ating on painted finishes This is designed to assist with infection control and is not a replacement for cleaning CAUTION Our products are NOT waterproof The equipment and accessories included charger...

Page 25: ...urther may cause damage to the movement and internal wiring of the light 5 5 Detaching Parts De construction of the lights should be done following a reverse order of the instructions in section 4 The...

Page 26: ...arm appears to move by itself and does not settle in the required position This can be rectified by adjusting the spring tension on the arm Next to the light head on the left side of the arm systems...

Page 27: ...he extension cable are fully connected For the mobile version ensure that the IEC is firmly pushed into the PSU Poor Light output Power Button Please check the variable intensity is not just set to it...

Page 28: ...4176 For any SPARE PARTS or TECHNICAL ISSUES phone DARAY S Service Delivery Team on 44 0 800 878 9864 Opening times 9am 5pm Monday to Thursday excluding bank holidays 9am 2 30pm on Friday Or email sup...

Page 29: ...ges may be applicable OTHER Any situation which is not covered by any of the above We will always try to help but we cannot normally offer a refund For additional clarification please refer to our ter...

Page 30: ...Daray s instructions Attachment of fittings and accessories not approved by Daray Repairs modifications carried out by service personnel not approved by Daray Damage caused by chemical corrosion from...

Page 31: ...Page 30 of 30 Service Notes...

Page 32: ...DARAY Ltd Edison House Robian Way Swadlincote Derbyshire United Kingdom DE11 9DH 44 0 800 878 9864 44 0 333 321 0973 sales daray co uk www daray co uk...

Reviews: