DARAY MAG700 Range Installation Manual Download Page 11

 

Page 10 of 19 

3.3 Wall version (MAG700LW) 

 

Wall brackets need to be true on all planes. 

 
 
 
 
 
 
 
 
 
 
 

3.3.1 Considerations 

 

Wall 
Construction 

Before fixing it is important to consider the strength of the wall 
and the depth of the fixings used.  
Use of a building engineer or structural drawings may be 
required to decide on suitability. 

Examinations 
to be 
undertaken 

For correct installation it will be necessary to decide the 
location of where you want the head to situate. This will be 
dependent on the specific requirements of your work / 
examinations, if in doubt consult the end user or DARAY. 

Locations of 
nearest power 

Only the supplied certified power connection should be used 
with the light.  
The length of this cable is approximately 1.6m so the wall 
mounted light should be within 1.3m of a mains power point 

Pivot W3 and 
W4 

Both the Pivot W3 and W4 are primarily designed for hardwired 
versions of the light.  
 
The PivotW3 is designed to be compatible with BESA Box style 
trunking (please note, reinforcement between the BESA trunking 
and the wall structure may be required). 
 
The PivotW4 incorporates a wide spreader plate with an optional 
hidden cable feed point. 
Use of a competent engineer as well as structural drawings may 
be required to decide on suitability. 

 

 

PivotW2 

PivotW3 

PivotW4 

Summary of Contents for MAG700 Range

Page 1: ...MAG700 Range LED Magnifier Light Operating Installation Manual QAM MAG700 0219 5...

Page 2: ...Page 1 of 19...

Page 3: ...ions 9 3 2 2 Placement and Installation 9 3 3 Wall version MAG700LW 10 3 3 1 Considerations 10 3 3 2 Placement and Installation 11 3 4 Mobile version MAG700LM 12 4 Maintenance 13 4 1 Maintenance sched...

Page 4: ...head and rigid arm system power supply module and the mount of choice The rigid spring balanced arm allows the light patch to be placed accurately and stably where it is needed All versions are delive...

Page 5: ...s Manual MAG703LD MAG703 LED 3 Dioptre Desk Mounted Magnifying Light MAG703LW MAG703 LED 3 Diotre Wall Mounted Magnifying Light MAG703LM MAG703 LED 3 Dioptre Mobile Magnifying Light MAG706LD MAG706 LE...

Page 6: ...25 000 hours Light head diameter 200mm Lens Diameter 125mm Magnification options 3 Dioptre 6 Dioptre 12 Dioptre Arm Length 800mm reach Input Voltage 100 240V AC 50 60Hz Output Voltage 24V DC 1A Warran...

Page 7: ...ts supplied by DARAY for fitting installation should be the following items in the specified quantities Desk Clamp Qty Desk Stand Qty MAG703 Magnifier Light or 706 712 1 MAG703 Magnifier Light or 706...

Page 8: ...all parts of the base are without visible damage 2 2 Adjusting the Lighthead The MAG700 head is secured using a large thumb screw This also controls the forward and backward motion of the head itself...

Page 9: ...pendent on couch height It may be necessary to adjust this height if there are specific medical procedures the light will be used for If in doubt consult the end user or DARAY When installing the brac...

Page 10: ...nt to consider the strength and thickness of the work surface and the suitability of the fixings used Use of an experienced fitter may be required 3 2 2 Placement and Installation PivotD2 Decide where...

Page 11: ...in doubt consult the end user or DARAY Locations of nearest power Only the supplied certified power connection should be used with the light The length of this cable is approximately 1 6m so the wall...

Page 12: ...mounting bracket and tighten the thumbscrew to lock the bracket onto the spigot Feed the cable through the silicone tubing and make the electrical connection Connect the grounding wire from the back o...

Page 13: ...d may require the use of a wooden or rubber mallet to tap the upstand downward Rest the mobile base on its side Push the bolt through the washer and weight plate Align the bolt with the threaded hole...

Page 14: ...ot and re grease as necessary Check all electrical connections are sound and that there is no visible cable wear All fixings to be checked and be of sound construction 4 2 Safety Precautions For all c...

Page 15: ...e our BioProtect antimicrobial coating on painted finishes This is designed to assist with infection control and is not a replacement for cleaning CAUTION Our products are NOT waterproof The equipment...

Page 16: ...t should not be opened and is not serviceable outside of a DARAY Authorised service centre For any issues requiring service work on the MAG700 please contact DARAY as unauthorised work will invalidate...

Page 17: ...DARAY S Service Delivery Team on 44 0 800 878 9864 Opening times 9am 5pm Monday to Thursday excluding bank holidays 9am 2 30pm on Friday Or email support daray co uk IF THE LIGHT WAS ORIGINALLY PURCH...

Page 18: ...rges may be applicable OTHER Any situation which is not covered by any of the above We will always try to help but we cannot normally offer a refund For additional clarification please refer to our te...

Page 19: ...Daray s instructions Attachment of fittings and accessories not approved by Daray Repairs modifications carried out by service personnel not approved by Daray Damage caused by chemical corrosion from...

Page 20: ...Page 19 of 19 Service Notes...

Page 21: ...Page 20 of 19...

Page 22: ...Page 21 of 19...

Page 23: ...Page 22 of 19...

Page 24: ...DARAY Ltd Edison House Robian Way Swadlincote Derbyshire United Kingdom DE11 9DH 44 0 800 878 9864 44 0 333 321 0973 sales daray co uk www daray co uk...

Reviews: