Settings
353
Copyright © DapTechnology B.V., 2005-2019 - All Rights Reserved., 5/20/2019
Please note that all available memory has to be assigned before the settings can be applied; there can be
no unused memory left.
20.2.6.8. Phy
Root Node
When checked, the Analyzer will always try to become the root node after a bus reset.
Phy Options
Disable Active Link bit at startup: When set the Analyzer will set no active link layer in SelfID packets.
This way the Analyzer looks like a "dumb" node on the bus.
Bus Power
This section is only available for the advanced series of analyzers.It contains a check box for each
Analyzer node. By enabling the check box for a specific node, this node will provide power to the 1394
bus.
Analyzers with only a single node will only show "Enable Bus Power".
The FireSpy3810 and the FireSpy3850 contain a VHDCI connector, the VHDCI power is not on the ports
itself but on the AUX cable.