20.2.6.7. Memory
The total memory is shown as the last item in the list. Part of the internal memory is allocated by the
Analyzer itself. This allocation is fixed and cannot be changed. The following fixed memory allocations
exist:
Internal Use
This part of the memory is used by the Analyzer itself for internal housekeeping.
Scriptor code & stack
This part of the memory is always allocated to the Scriptor for storing the code of a script and the stack it
uses.
The following parts of internal memory can be allocated by the user. Note that the Recorder, Generator
and Scriptor need to be cleared before their memory allocation can be changed.
Scriptor Data
This part of the memory is used for the heap of the scriptor and the parts of the code and stack that do not
fit in the fixed allocation. The heap is used to store large data objects like packets, file stream buffers and
the control output buffer.
Recorder
This part of the memory is used to store all packets and bus events recorded by the recorder.
API Data
This part of the memory is used by the API.
Generator
This part of the memory is used by the generator data for sending Isochronous packets.
Summary of Contents for 1394
Page 1: ...1394 Analyzer Operation Manual Hardware and Software Guide Doc DT PRO134MAN700E ...
Page 11: ...1394AnalyzerOperationManual 11 456 The SCSI2 Connector 457 The SUBD connector ...
Page 187: ...Scriptor 187 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...
Page 199: ...Scriptor 199 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...
Page 363: ...FormatEditor 363 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...