Dantherm CS030040A Product Information Manual Download Page 1

 

 

 

AC-4 CS030040 4K Manual Rev DD 

 

Page 1 of 17 

Dantherm, Inc. 
110 Corporate Drive, Suite K 
Spartanburg, SC 29303 
Tel #+1 864 595 9800 
Fax # +1 864 595 9810 
Email:  [email protected]  
Website:  www.dantherm.com

 

 

 

Panel Mounted Air Conditioners  

by Dantherm, Inc. 

 
 

 

 

CS030040A/B with USACG-6 Control 

PRODUCT INFORMATION MANUAL 

 

Summary of Contents for CS030040A

Page 1: ...Inc 110 Corporate Drive Suite K Spartanburg SC 29303 Tel 1 864 595 9800 Fax 1 864 595 9810 Email dantherm usa dantherm com Website www dantherm com Panel Mounted Air Conditioners by Dantherm Inc CS030040A B with USACG 6 Control PRODUCT INFORMATION MANUAL ...

Page 2: ... 1 USACG 6 CONTROLLER DIAGRAM 8 5 2 MODIFY HEATING SET POINT 8 5 3 MODIFY COOLING SET POINT 9 5 4 CHANGE UNIT OF MEASURE 9 5 5 DEBUGGING THE SYSTEM 9 5 5 1 Observing the return temperature and fault codes 9 5 5 2 Initiating the TEST sequence 10 5 5 3 Resetting the controller to factory defaults 10 6 MAINTENANCE 11 6 1 PREVENTATIVE MAINTENANCE SCHEDULE 11 6 2 EVAPORATOR AND CONDENSER COIL CLEANING ...

Page 3: ...re UL recognized and tested to UL484 It will comply where necessary with the safety requirements as defined in UL484 When servicing the unit do not remove the cover s for 5 minutes after switching the unit off to allow pipe work compressor discharge to cool 2 UNPACKING HANDLING INITIAL INSPECTION The air conditioner should be inspected on initial delivery and any damage to packaging noted The unit...

Page 4: ...emoval Voltage Hz Ph Cooling Current Amps Heating Current Amps Approx Weight lbs Kg CS030040A H012 4000 1172 115V 60 1 10 9 10 5 100 45 CS030040B H015 4000 1172 230V 50 60 1 5 0 6 5 100 45 Rating capacity shown based on 95 F return air temperature to cabinet in 95 F ambient conditions at nominal voltage and unimpeded resistance to air flow C CLASSIC S Standard Configuration 030 Height of Unit 30 0...

Page 5: ...Air Conditioner 4000 Installation Operating Maintenance Manual AC 4 CS030040 4K Manual Rev D Page 5 of 17 4 DIMENSIONS INSTALLATION 4 1 Product Drawing ...

Page 6: ...Air Conditioner 4000 Installation Operating Maintenance Manual AC 4 CS030040 4K Manual Rev D Page 6 of 17 4 2 Mounting template ...

Page 7: ...y is used All installations are to be completed in accordance with local NEC codes and guidelines The electrical circuit should be protected by a slow blow breaker or fuse of suitable rating The alarm is a Form C type relay 50 VDC 0 1A Max The connections for alarm are the red Common black Normally open and white Normally closed wires only The green wire is not used If the interconnect function is...

Page 8: ...roller via the RS 232 serial port connected to a PC with HyperTerminal Access the controller by removing the unit front cover Adjusting the factory controller settings may alter performance and affect warranty 5 1 USACG 6 Controller diagram 5 2 Modify heating set point 1 Press L button for 2 seconds and release Display will begin Display Mode 2 Press L R button simultaneously for 2 seconds and rel...

Page 9: ...in Display Mode 2 Press L R button simultaneously for 2 seconds and release Display will show test 3 Press R button for 2 seconds and release Display will show H SP 4 Press R button for 2 seconds and release Display will show C SP 5 Press R button for 2 seconds and release Display will show unit 6 Press L button for 2 seconds and release Display will show current Unit of measure a Press and hold R...

Page 10: ...how test step 4 TEST steps STEP DESCRIPTION LED INT FAN HEATER COMP COND FAN DURATION 0 Display S W Revision Level X XX ON OFF OFF OFF 10 SEC 1 Int Fan only T01 ON OFF OFF OFF 30 SEC 2 Heater T02 ON ON OFF OFF 35 SEC 3 Int Fan only T03 ON OFF OFF OFF 20 SEC 4 Con Fan T04 ON OFF OFF Cycle 30 SEC 5 Comp and cond T04 ON OFF ON ON 75 SEC 6 Int Fan only T05 ON OFF OFF OFF 30 SEC 5 5 3 Resetting the con...

Page 11: ... the coils should be cleaned Once the coils become visibly coated with dust it is recommended that they be cleaned with a brush or compressed air Both sides of the coils should be inspected The condenser coil may be washed with a commercial coil cleaning solution Under no circumstance must the access port covers be removed adjusted or tampered with other than by a certified technician All maintena...

Page 12: ...possible using suitably qualified personnel to repair the unit in the field If the refrigerant charge is lost the means of leakage should be established and repaired by a reputable refrigeration repair company Ports are provided for checking suction and discharge pressures and recharging if required The type of refrigerant and charge amount is detailed on the product label attached to the unit Not...

Page 13: ...d for application Contact Dantherm Inc Failed evaporator blower Replace evaporator blower motor or assembly Condensate draining continuously Enclosure not properly sealed Check and seal all openings Excessive vibration Loose compressor fans or tubing Locate and correct Missing Compressor Current F 01 Wire detached or improperly installed Secure wiring or install wiring properly according to diagra...

Page 14: ...Air Conditioner 4000 Installation Operating Maintenance Manual AC 4 CS030040 4K Manual Rev D Page 14 of 17 6 8 Wiring Diagram 6 8 1 CS030040 Shown with 1200W or 1500W Heater ...

Page 15: ...Air Conditioner 4000 Installation Operating Maintenance Manual AC 4 CS030040 4K Manual Rev D Page 15 of 17 6 9 Spare Parts Guide ...

Page 16: ...r of the warranty period of the original product This warranty does not cover damages or repairs caused by improper installation misuse of the product negligent servicing improper applications unauthorized modifications improper electrical supply failure to follow manufacturer s instructions and rating plate information accidents natural disasters damage in transportation lack of normal preventive...

Page 17: ...ntherm Inc part number s of product to be returned Dantherm Inc serial number s of product to be returned Number of units requested to be returned Reason for return Contact name phone and fax number Date of product receipt Invoice number and purchase order number covering the unit s The customer is responsible for suitably packaging the unit s securely ideally in the original packaging marking all...

Reviews: