OPERATION
O
peration of the 46022-30 module is a function of the MAP
firmware. A front panel LED labeled CHAN ENB indicates
when the address (channel) that it is set for becomes active.
Refer to the appropriate firmware manual for information on
how the unit functions within the 460 ACS.
PIN NUMBER
1
2
3
17
19
20
21
49008 (RS-422)
RX+
RX-
--
GND
TX+
TX-
--
49009 (RS-232)
RD
--
CF
GND
--
TD
CA
49013 (202 TONE)
RCV
RCV
DIST RCV
GND
XMT
XMT
DIST XMT
T
ABLE
B - S
UBASSEMBLY
P
IN
C
ONNECTIONS
TECHNICAL SPECIFICATIONS
DESCRIPTION
Input Voltage
Input Current (w/o subassembly)
Idle
Operating
Heat Dissipation (w/o subassembly)
Output Current (Max.) & Voltage
@ pin 45
@ pin 47
@ pin 49
Weight (w/o subassembly)
Physical dimensions
Operating Temperature Range
VALUE
-21 to -56 VDC
@ -21 VDC
@ -24 VDC
@ -48 VDC
@ - 56 VDC
48 mA
47 mA
44 mA
43 mA
50 mA
48 mA
45 mA
44 mA
3.6 Btu/Hr
4.0 Btu/Hr
7.4 Btu/Hr
8.5 Btu/Hr
200 mA @ +5 VDC
20 mA @ +12 VDC
20 mA @ -12 VDC
6.5 Ounces
1.4" x 6.0" x 5.6"
0° to 60° C.