Dantel 46020 Installation & Operation Manual Download Page 1

CAUTION

•

Install or remove modules from the shelf only when the power is off.
If you install a module in the shelf with the power on, the internal

circuitry may suffer damage and the product warranty will be void.

•

Remove and install circuit boards only in a static-safe environment
(use antistatic wrist straps, smocks, footwear, etc.).

•

Keep circuit boards in their antistatic bags when they are not in use.

•

Do not ship or store circuit boards near strong electrostatic, electromag-
netic, magnetic, or radioactive fields.

•

For more complete information on electrostatic discharge safety
precautions, refer to Bellcore

TM

 Technical Reference # TR-NWT-000870.

Copyright 1997 by Dantel, Inc. • Dantel is a registered trademark of Dantel, Inc. • ISO 9001 Registered

Printed in the U.S.A.

I

NSTALLATION

 & O

PERATION

 M

ANUAL

46020-1297 <90-00038>

46020

M

ULTIPLE

 A

LARM

P

ROCESSOR

About this Practice:

• This practice has been reissued to

meet ISO 9001 requirements.

Issue date:  July 1997

Reissued Practices: Updated and
new content can be identified by a
banner in the right margin.

UPDATED

Table of Contents

Ordering Information ...........................................................................  2
General Description..............................................................................  2
Circuit Description ...............................................................................  2
Installation............................................................................................  4
Operation ..............................................................................................  7
Technical Specification .........................................................................  7
Warranty ...............................................................................................  8

46020-00

MULTI-ALARM

PROCESSOR

A1146020-00 REV__

XMT DATA

RESET

Summary of Contents for 46020

Page 1: ...nformation on electrostatic discharge safety precautions refer to BellcoreTM Technical Reference TR NWT 000870 Copyright 1997 by Dantel Inc Dantel is a registered trademark of Dantel Inc ISO 9001 Regi...

Page 2: ...l points using serial ports or Dantel s 46028 Control Point Modules CPMs I O devices can include computers dumb terminals and alarm system components by other manufacturers The MAP is a plug in printe...

Page 3: ...Transmit Data RXD Receive Data 32 31 30 29 39 41 40 42 23 24 25 26 46 45 43 44 54 51 53 55 50 49 56 52 8 MEMORY MEMORY MEMORY MEMORY DECODER PORT 3 MASTER ADR CPU ADR PARALLEL INPUT OUTPUT 35 17 POWER...

Page 4: ...n the power supply provides operating power for an optional communications subassembly CIRCUIT DESCRIPTION INSTALLATION This sections consists of installing the communication subas sembly if necessary...

Page 5: ...he documentation for the firmware installed on the MAP Module Mounting Normally the 56 pin edge connector in the shelf is prewired at the factory If you are going to wire the connector refer to Fig 3...

Page 6: ...3 W3 W2 DTR DCD RD RTS RTS EXTERNAL INTERRUPT PRINTER PORT PRINTER PORT MULTIPLE ALARM COMBINER AUXILIARY INPUT OUTPUT MULTIPLE ALARM COMBINER LEVEL A LEVEL C SUMMARY ALARM MODULE R3 R1 DTR DSR CTS TT...

Page 7: ...ort A button labeled RESET is recessed below the level of the front panel and is used to manually reset the MAP s microprocessor and associated circuitry TECHNICAL SPECIFICATION DESCRIPTION Input Volt...

Page 8: ...instrument signed by a duly authorized officer of the Seller and accepted by the Buyer Warranty and remedies on products not manufactured by the Seller are in accordance with warranty of the respecti...

Reviews: