Dantel 44022-00 Installation & Operation Manual Download Page 2

P

AGE

 2

44022-00-0898 <90-00023>

ORDERING INFORMATION

GENERAL DESCRIPTION

T

he 44022 Subscriber Line Interface Module (44022)

interfaces a subscriber telephone to a four-wire port. The

44022 also provides group or all-call capability for the Dantel

00330 DTSS3A Selective Signaling Order-Wire Terminal.
The 44022 comes with with two model options, the 44022-00 and

the 44022-10. This practice covers only the 44022-00. The

44022-10 is covered in a separate practice. The 44022-00 is

recommended for applications that do not require an external

ringing generator. The 44022-10 should be used in all applica-

tions requiring an external ringing generator.
The 44022 is a plug-in printed circuit module that fits into any

400-type or similar equipment housing. The 44022 does not

accept subassemblies.
The front panel includes:

Operational status indicating LEDs

Calibration test points

Test jacks

Level controls

A test/reset switch

The 44022 operates on -21 to -56 VDC input power.

CIRCUIT DESCRIPTION

T

he Decoder Module circuitry consists of three sections:

audio, signaling/control and power regulator. Fig. 1 shows the

44022 Subscriber Line Interface Module audio section functional

schematic. Fig. 2 shows the 44022 Subscriber Line Interface

Module signaling/control section functional schematic.

NOTE:

This section lists the different options available for this product. To order any of the avail-

able options, contact Dantel Inside Sales through our toll-free number, 

1-800-432-6835.

OPTION NUMBER

FEATURES

B11-44022-00

Subscriber Line Interface

A11-44022-10

Subscriber Line Interface

Summary of Contents for 44022-00

Page 1: ...efer to BellcoreTM Technical Reference TR NWT 000870 Copyright 1998 by Dantel Inc Dantel is a registered trademark of Dantel Inc ISO 9001 Registered Printed in the U S A INSTALLATION OPERATION MANUAL...

Page 2: ...module that fits into any 400 type or similar equipment housing The 44022 does not accept subassemblies The front panel includes Operational status indicating LEDs Calibration test points Test jacks L...

Page 3: ...ENABLE ALERT ENABLE ON HOOK TONE ON HOOK ENABLE RING BACK TONE RING BACK ENABLE LINE 4W XMT DISTRIBUTION OUTPUT OFF HOOK SENSE RING TRIP SENSE R38 DROP 4W RCV T3 600 600 0 0 IMPEDANCE 4W 4W 2W 2W IN O...

Page 4: ...C DELAY 1 5 SEC TIMER BUSY TONE EN EXTERNAL BUSY LIGHT L ONE SHOT 22 TEST SW CLR PWR UP CLR MAN CLR 1 3 SEC DELAY 1 3 SEC TIMER 90 SEC TIMER 1 5 SEC TIMER 3 21 LATCH REMOTE M LEAD CONTROL IN OUT 24 GP...

Page 5: ...onitor output The monitor output mutes when you remove the ground from pin 27 The signal passing through the mute FET goes through a variable gain amplifier to an impedance strap option If you strap t...

Page 6: ...y input pin 22 If the privacy strap is in the circuit BUSY LED lights up and the external busy light output pin 19 turns on ground The lamp lead pin 12 also turns on battery A busy tone enable turns o...

Page 7: ...on occurs during the ringing cycle the 44022 detects the loop current releases relay K1 and the front panel OFF HOOK LED lights up The 44022 generates an off hook tone enable which applies an off hook...

Page 8: ...3 shows a DTSS3A application FEATURES The 44022 00 module offers features which can be made opera tional when the module is installed Some features are selected by making wiring connections at the edg...

Page 9: ...re a full duplex radio is used for the communications system the M lead operates the radio s CD Carrier Detect output All Call and Group Call The all call input at pin 28 and group call input at pin 2...

Page 10: ...option Both mini jumpers must be installed for the module to function Install the jumpers horizontally for four wire phones Install both jumpers vertically for two wire phones Four wire is recommended...

Page 11: ...k Phone Jack P3 2 P3 1 Busy Rst In 49018 or 49028 4 12 3 14 Reset In Ring Start Pwr up Clear Gnd V 35 17 39 13 15 8 7 44020 DTMF Decoder Module J3 Gnd J6 J1 18 J1 18 Power 22 to 56 VDC D1 J5 55 49 Rin...

Page 12: ...m LINE TRANSMIT 4 WIRE XMT LEVEL 3 dBm to 7 dBm 16 dBm to 3 dBm REMOTE M LEAD CONTROL By incoming call with radios By subscriber off hook PRIVACY Automatic or Manual Privacy No Privacy normal for orde...

Page 13: ...st Set or any 600 ohm audio oscillator NOTE You only need a test oscillator when you test the 44022 SLIM in an assembly that does not have a 44011 Line Interface Module You can normally use the test o...

Page 14: ...e R 4W XMT Line T Distribution Output Power Up Clear On Hook Tone Input Speaker Monitor Out Off Hook Tone Input Battery Busy Tone Input Forced Disconnect Ringback Tone Input Ring Generator Input use w...

Page 15: ...move the meter and test oscillator connections Insert the test oscillator at the DROP TRANSMIT jack Note If the LED does not light the oscillator is not providing a resistive path to ground Place a 60...

Page 16: ...ont panel LEDs The BUSY LED indicates the system is busy The INC CALL LED indicates an incoming call The LED pulsates with the ringing signal The OFF HOOK LED lights up when the subscriber phone is of...

Page 17: ...ipation Idle Full Load Physical Dimensions Weight Operating Temperature Range VALUE 300 Hz to 3400 Hz 0 5 dB 20 dB 250 ohms 24 VDC nominal 1000 ohms 48 VDC nominal 16 to 7 dBm 16 to 7 dBm 10 dBm 10 dB...

Page 18: ...en instrument signed by a duly authorized officer of the Seller and accepted by the Buyer Warranty and remedies on products not manufactured by the Seller are in accordance with warranty of the respec...

Reviews: