OPERATION
T
his Off-Net package allows any station in the order wire
system to access a Telco central office or PABX line. The
Telco central office or PABX line accesses the touch-tone into the
public-switched telephone network. Conversely, an outside party
can call into the order wire network and selectively dial any
station desired.
To call out from any terminal on the order wire system:
1.
Pick up the handset and press #.
2.
Dial the outside access code and listen for dial tone.
3.
Dial the desired outside number.
4.
To terminate the call, press #.
To call into the order wire system from the outside:
1.
Access the seven digit number for the outside Telco line associated
with the off-net. The caller hears one ring, followed by a short tone
burst.
2.
Dial the desired order wire station code. The caller will hear a ring-
back tone until the party answers.
In a loop trunk, the person at the answering order wire station
must dial a * or # or the call terminates in 10 to 80 seconds.
Terminate the call by hanging up or dialing # (or * if the call
was answered by dialing #).
NOTE:
When using two-wire lines under loop control with no wink, the
person at the called order wire station must dial a * within
10 to 80 seconds (adjustable) or an automatic disconnect
occurs. (The * overrides the disconnect.) To terminate the call,
dial #. These are factory options and may be reversed if
desired. Refer to the 49018 practice for strapping options.
Neither step is necessary when using loop control with wink or
ground start trunks.
A
LIGNMENT
P
ROCEDURE
The 00331 DTSS3ON Order Wire system comes from the factory
with all switch, strap, and level settings set. If the levels re-
quired are different than the standard level settings, use the
procedure described in Table C.
The equipment neccessary is a transmission test set capable of
serving as a:
♦
Signal Generator sending a 1kHz, 600 ohn signal at various
levels
♦
600 ohm level Meter (with and without 600 ohm termina-
tion).