Setting the Monitoring Function
System KMP-V is delivered with pre-set default factory settings, but may be easily
adapted to the actual installation by the relocation of jumpers on the circuit board
mounted in the lid of the enclosure.
A jumper is a small black plastic clip with an integral metal shunt which will connect two
metal pins on the circuit board when inserted over these. A pair of small tweezers or
needle-nose pliers may be helpful for the relocation of jumpers.
CAUTION! Disconnect the mains supply before opening the Control Unit enclosure!
Several locations accept no more than one jumper. If too many are installed, or if a
jumper is located inappropriately, the system may object by an intermittent beep while on
the front panel indicating the number of the problem row by blinking with the
corresponding indicator. E.g., blinking the 2
nd
LED from the top indicates an error in
jumper row B.
Jumper (enlarged).
Face and side views.