Page 29 of 65
Generate 122 (Acknowledge back quote)
If a MF/HF DSC message format 120 (Selective) and category 100 (Routine), 108 (Safety) or
110 (Urgency) and 117 (Ack. RQ) are received, the FUTRONIC MKII is able to generate a 122
(Ack. BQ). After Receiving the message, the message is shown on the Display. When Exiting
the results view, the following message is shown in the display.
Send Acknowledge
Skip Ack
Select Ack for transmitting the Ack. BQ message. Remember to connect the antenna to RF Out
on the FUTRONIC MKII.
Example of printout from the memory if the MF/HF DSC message is received:
MF/HF # 2 Time/date: 08:35:07 / 29-01-2020
DSC DATA: 12577.0 kHz
RX MMSI: 9999999990 Format 120 Category: 100 TX MMSI: 2190155210
1.telecommand: 109 2.telecommand: 126 Info.: 12 35 30 12 35 30
EOS: 117 ECC: 94 Status: OK
Mark: 12576916 Hz Space: 12577085 Hz
MF/HF # 2 Time/date: 08:35:28 / 29-01-2020
12577.0 kHz Received ok
Send DSC
In the Send DSC mode, the test box will transmit a DSC call for you to check on the DSC
receiver accordingly.
It is a requirement that the MMSI number registered in the test box is identical with the MMSI of
the radio to
be tested. Please check and change number, if required, using the Edit ship’s MMSI
menu. See Page 12.
With selective calls, connect the relevant antenna supplied with the test box to RF OUT and use
the setup below. The test box antenna should be able to “see” the transmitter’s antenna.
DSC RECEIVER
ANT.