STEP 12
(Attaching The Power Unit Hose)
The power unit hydraulic hose assembly must be routed through the clips in powerside safety cover.
Failure to do so can result in personal injury or damage to the
lift.
1. With powerside safety cover loosely positioned route power
unit hydraulic hose through clips in powerside safety cover.
(See figure 20)
2. Install the 90 degree o-ring fitting into the power port of the
power unit, do not use teflon on this fitting. The power port is
identified by the red plastic plug. Connect the straight fitting
on the power unit hose assembly to the 90 degree o-ring fit-
ting on power unit. (See figure 21)
3. Connect other end of power unit hydraulic hose assembly to
the bulkhead fitting. (See figure 22)
4. After safeties have been adjusted and checked for proper op-
eration, install and tighten powerside safety cover and offside
safety cover, make sure you tighten the jam nut on the inside
of the cover as well. (See figure 23)
STEP 13
(Installing The Overhead Micro Switch)
ALL WIRING MUST BE PERFORMED BY A LICENSED ELECTRICIAN. DO NOT PERFORM ANY MAIN-
TENANCE OR INSTALLATION OF ANY COMPONENTS WITH OUT FIRST ENSURING THAT ELECTRICAL
POWER HAS BEEN DISCONNECTED AT THE SOURCE OR PANEL AND CANNOT BE RE-ENERGIZED
UNTIL ALL MAINTENANCE AND / OR INSTALLATION PROCEDURES ARE COMPLETED.
1. Install the overhead micro switch as shown. (See figure 24)
WARNING
Fig: 20
Shown with
breakout to
show hose clip
Fig: 23
Shown with
breakout to
show jam nut
Fig: 22
Shown with
breakout to
show bulkhead
Fig: 21
DANGER
Summary of Contents for D-10 Series
Page 1: ...A ND VALIDATE D Rev D 06202018 P N 199824...
Page 46: ......
Page 47: ...D10ACX...
Page 52: ...Dannmar R EQUIPMENT...